| VH1B | VH2B | VH3B | VH4/AB | VH4B | VH5B | |||
|---|---|---|---|---|---|---|---|---|
| Output current (maximum) | 19A at 40°C (ambient) | 19A at 40°C (ambient) | 19A at 40°C (ambient) | 19A at 40°C (ambient) | 19A at 40°C (ambient) | 19A at 40°C (ambient) | ||
| Connectable unit | VAM150FA | VAM250FA, VAM350FB | VAM500FB, VAM650FB | VAM800FB, VAM1000FB | VAM800FB, VAM1000FB | VAM1500FB, VAM2000FB | ||
| LED indicators | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | Power ON - Yellow, Heater ON - Red (solid or flashing, indicating pulsed control), Airflow fault - Red | ||
| Run relay | 1A 120V AC or 1A 24V DC | 1A 120V AC or 1A 24V DC | 1A 120V AC or 1A 24V DC | 1A 120V AC or 1A 24V DC | 1A 120V AC or 1A 24V DC | 1A 120V AC or 1A 24V DC | ||
| Duct diameter | mm | 100 | 150 | 200 | 250 | 250 | 350 | |
| Capacity | kW | 1.0 | 1.0 | 1.0 | 2.5 | 1.5 | 2.5 | |
| Mounting holes | 98mm x 181mm centres 5mm Ø holes | 98mm x 181mm centres 5mm Ø holes | 98mm x 181mm centres 5mm Ø holes | 98mm x 181mm centres 5mm Ø holes | 98mm x 181mm centres 5mm Ø holes | 98mm x 181mm centres 5mm Ø holes | ||
| Maximum ambient adjacent to terminal box | 35°C (during operation) | 35°C (during operation) | 35°C (during operation) | 35°C (during operation) | 35°C (during operation) | 35°C (during operation) | ||
| Temperature sensor | 5k ohms at 25°C (table 502 1T) | 5k ohms at 25°C (table 502 1T) | 5k ohms at 25°C (table 502 1T) | 5k ohms at 25°C (table 502 1T) | 5k ohms at 25°C (table 502 1T) | 5k ohms at 25°C (table 502 1T) | ||
| BMS setpoint input | 0-10VDC | 0-10VDC | 0-10VDC | 0-10VDC | 0-10VDC | 0-10VDC | ||
| Temperature control range | 0 to 40°C / (0-10V 0-100%) | 0 to 40°C / (0-10V 0-100%) | 0 to 40°C / (0-10V 0-100%) | 0 to 40°C / (0-10V 0-100%) | 0 to 40°C / (0-10V 0-100%) | 0 to 40°C / (0-10V 0-100%) | ||
| Control fuse | 20 x 5mm 250 mA | 20 x 5mm 250 mA | 20 x 5mm 250 mA | 20 x 5mm 250 mA | 20 x 5mm 250 mA | 20 x 5mm 250 mA | ||
| Power supply | Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
| Voltage | V | 220/250 | 220/250 | 220/250 | 220/250 | 220/250 | 220/250 | |