| VAM350J8VEB | VAM500J8VEB | VAM650J8VEB | VAM800J8VEB | VAM800J8VEB9 | VAM1000J8VEB | VAM1000J8VEB9 | VAM1500J8VEB | VAM1500J8VEB9 | VAM2000J8VEB | VAM2000J8VEB9 | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Power input - 50Hz | Heat exchange mode | Nom. | Ultra high | kW | 0.097 (1) | 0.164 (1) | 0.247 (1) | 0.303 (1) | 0.303 (1) | 0.416 (1) | 0.416 (1) | 0.548 (1) | 0.548 (1) | 0.833 (1) | 0.833 (1) |
| Bypass mode | Nom. | Ultra high | kW | 0.085 (1) | 0.148 (1) | 0.195 (1) | 0.289 (1) | 0.289 (1) | 0.417 (1) | 0.417 (1) | 0.525 (1) | 0.525 (1) | 0.835 (1) | 0.835 (1) | |
| Casing | Material | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | Galvanised steel plate | |||
| Dimensions | Unit | Height | mm | 305 | 305 | 368 | 368 | 368 | 368 | 368 | 731 | 731 | 731 | 731 | |
| Width | mm | 1113 | 1113 | 1354 | 1354 | 1,354 | 1354 | 1,354 | 1354 | 1,354 | 1354 | 1,354 | |||
| Depth | mm | 866 | 866 | 920 | 1172 | 1,172 | 1172 | 1,172 | 1172 | 1,172 | 1172 | 1,172 | |||
| Weight | Unit | kg | 46.5 | 46.5 | 61.5 | 76.5 | 76.5 | 76.5 | 76.5 | 160 | 160 | 160 | 160 | ||
| Fan | Air flow rate - 50Hz | Heat exchange mode | Ultra high | m³/h | 350 (1) | 500 (1) | 650 (1) | 800 (1) | 800 (1) | 1000 (1) | 1,000 (1) | 1500 (1) | 1,500 (1) | 2000 (1) | 2,000 (1) |
| Bypass mode | Ultra high | m³/h | 350 (1) | 500 (1) | 650 (1) | 800 (1) | 800 (1) | 1000 (1) | 1,000 (1) | 1500 (1) | 1,500 (1) | 2000 (1) | 2,000 (1) | ||
| External static pressure - 50Hz | Ultra high | Pa | 90.0 (1) | 90.0 (1) | 90.0 (1) | 90.0 (1) | 90 | 90.0 (1) | 90 | 90.0 (1) | 90 | 90.0 (1) | 90 | ||
| Operation range | Min. | °CDB | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | -10 (2) | ||
| Max. | °CDB | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | 46 | |||
| Relative humidity | % | 80 or less | 80 or less | 80 or less | 80 or less | 80% or less | 80 or less | 80% or less | 80 or less | 80% or less | 80 or less | 80% or less | |||
| Around unit | °CDB | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | 0°C~40°CDB, 80% RH or less | |||
| Sound pressure level - 50Hz | Heat exchange mode | Ultra high | dBA | 34.5 (1) | 37.5 (1) | 39.0 (1) | 39.0 (1) | 39 | 42.0 (1) | 42 | 42.0 (1) | 42 | 45.0 (1) | 45 | |
| Bypass mode | Ultra high | dBA | 34.5 (1) | 38.0 (1) | 38.0 (1) | 40.0 (1) | 40 | 42.5 (1) | 42.5 (1) | 42.0 (1) | 42 | 45.0 (1) | 45 | ||
| Heat exchange system | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | Air to air cross flow total heat (sensible + latent heat) exchange | ||||
| Heat exchange element | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | Specially processed non-flammable paper | ||||
| Connection duct diameter | mm | 200 | 200 | 250 | 250 | 250 | 250 | 250 | 2x250 | 2x250 | 2x250 | 2x250 | |||
| Operation mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | Heat exchange mode, bypass mode, fresh-up mode | ||||
| Sound power level (Lwa) | dB | 51 | 54 | 58 | 58 | 58 | 61 | 61 | 62 | 62 | 65 | 65 | |||
| Power supply | Name | VE | VE | VE | VE | VE | VE | VE | VE | VE | VE | VE | |||
| Phase | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | 1~ | ||||
| Frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | |||
| Voltage | V | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | 220-240/220 | |||
| Notes | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | (1) - Measured according to JIS B 8628 - 2003 | ||||
| (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | (2) - When the heat reclaim ventilation unit is installed upside down, the minimal allowed outdoor air temperature is 5°C. | |||||
| (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | (3) - In accordance with commission regulation (EU) No 1253/2014 | |||||
| (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | (4) - Measured according to EN308 : 1997 | |||||
| (5) - In accordance with regulation (EU) No 327/2011 | (5) - In accordance with regulation (EU) No 327/2011 | (5) - In accordance with regulation (EU) No 327/2011 | (5) - In accordance with regulation (EU) No 327/2011 | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - In accordance with regulation (EU) No 327/2011 | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - In accordance with regulation (EU) No 327/2011 | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | (5) - In accordance with regulation (EU) No 327/2011 | (5) - Clean the filter when the filter icon appears on the controller screen. Regular filter cleaning is important for delivered air quality and for the unit's energy efficiency. | |||||
| (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | (6) - In accordance with regulation (EU) No 327/2011 | ||||||||||||
| (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | (7) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. | ||||||||||||
| (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | (8) - MCA= 1,25x(FLA(FM1)+FLA(FM2)+FLA(FM3)+FLA(FM4)) | ||||||||||||
| (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | (9) - MCA represents maximum input current. | ||||||||||||
| (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | (10) - MFA ≤ 4 x (FLA(FM1)+FLA(FM2)+...) | ||||||||||||
| (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | (11) - Select wire size based on the value of MCA | ||||||||||||
| (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | (12) - Fan step 8 is nominal specs. | ||||||||||||
| (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | (13) - The unit complies for "Code du travail" and "ERP 5e catégorie" applications according to French legislation. | ||||||||||||
| (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | (14) - "Code du travail" applications are non-public buildings (example offices). | ||||||||||||
| (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | (15) - "ERP (Etablissement Recevant du Public) de 5e catégorie" are smaller shops, hotels etc | ||||||||||||