RZAG71M7Y1B |
RZAG100M7Y1B |
RZAG125M7Y1B |
RZAG140M7Y1B |
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
|
51
|
52
|
52
|
|
Cooling
|
Nom.
|
dBA
|
|
47
|
50
|
51
|
Standard Accessories
|
Tie-wraps
|
2
|
2
|
2
|
2
|
|
Installation manual
|
1
|
1
|
1
|
1
|
|
Refrigerant label for F-gas regulation
|
1
|
1
|
1
|
1
|
|
General safety precautions
|
1
|
1
|
1
|
1
|
|
LOT10 Energy Label
|
1
|
1
|
1
|
1
|
Refrigerant
|
Charge
|
TCO2Eq
|
|
2.53
|
2.53
|
2.53
|
|
GWP
|
|
|
675
|
675
|
675
|
|
Charge
|
kg
|
|
3.75
|
3.75
|
3.75
|
|
Type
|
|
|
R-32
|
R-32
|
R-32
|
Piping connections
|
Liquid
|
OD
|
mm
|
|
9.52
|
9.52
|
9.52
|
|
Piping length
|
OU - IU
|
Max.
|
m
|
|
85
|
85
|
85
|
|
|
System
|
Chargeless
|
m
|
|
40
|
40
|
40
|
|
|
|
Equivalent
|
m
|
|
100
|
100
|
100
|
|
Gas
|
OD
|
mm
|
|
15.9
|
15.9
|
15.9
|
|
Level difference
|
IU - IU
|
Max.
|
m
|
|
0.5
|
0.5
|
0.5
|
|
|
IU - OU
|
Max.
|
m
|
|
30.0
|
30.0
|
30.0
|
|
Additional refrigerant charge
|
kg/m
|
|
See installation manual
|
See installation manual
|
See installation manual
|
Sound power level
|
Cooling
|
dBA
|
|
66
|
69
|
70
|
|
Heating
|
dBA
|
|
|
69 (1)
|
70 (1)
|
Dimensions
|
Unit
|
Width
|
mm
|
|
940
|
940
|
940
|
|
|
Depth
|
mm
|
|
320
|
320
|
320
|
|
|
Height
|
mm
|
|
1,430
|
1,430
|
1,430
|
Compressor
|
Type
|
|
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Hermetically sealed swing compressor
|
Weight
|
Unit
|
kg
|
|
92
|
92
|
92
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
|
16
|
16
|
16
|
Power supply
|
Phase
|
|
|
3~
|
3~
|
3~
|
|
Frequency
|
Hz
|
|
50
|
50
|
50
|
|
Voltage
|
V
|
|
380-415
|
380-415
|
380-415
|
Notes
|
|
(1) - According to ENER Lot 21
|
(1) - According to ENER Lot 21
|
(1) - According to ENER Lot 21
|
|
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
|
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
|
|
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase.
|
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase.
|
(4) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase.
|
Dimensions
|
Unit
|
Height
|
mm
|
990
|
|
|
Width
|
mm
|
940
|
|
|
Depth
|
mm
|
320
|
Weight
|
Unit
|
kg
|
70
|
Compressor
|
Type
|
|
Hermetically sealed swing compressor
|
Operation range
|
Cooling
|
Ambient
|
Min.
|
°CDB
|
-20
|
|
|
|
Max.
|
°CDB
|
52
|
|
Heating
|
Ambient
|
Min.
|
°CWB
|
-20
|
|
|
|
Max.
|
°CWB
|
18.0
|
Sound power level
|
Cooling
|
dBA
|
65
|
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
46
|
|
Heating
|
Nom.
|
dBA
|
49
|
Refrigerant
|
Type
|
|
R-32
|
|
Charge
|
kg
|
2.95
|
|
GWP
|
|
675
|
|
Charge
|
tCO2Eq
|
1.99
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
|
Gas
|
OD
|
mm
|
15.9
|
|
Piping length
|
OU - IU
|
Max.
|
m
|
55
|
|
|
System
|
Equivalent
|
m
|
75
|
|
|
|
Chargeless
|
m
|
40
|
|
Additional refrigerant charge
|
kg/m
|
See installation manual
|
|
Level difference
|
IU - OU
|
Max.
|
m
|
30.0
|
|
|
IU - IU
|
Max.
|
m
|
0.5
|
Power supply
|
Phase
|
|
3~
|
|
Frequency
|
Hz
|
50
|
|
Voltage
|
V
|
380-415
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
16
|