Specifications Table for RXYSQ-T7Y1B9

RXYSQ6T7Y1B9
Sound pressure level Cooling Nom. dBA 51 (5)
Standard Accessories Installation manual Installation manual
  Operation manual Operation manual
  Connection pipes Connection pipes
Capacity range HP 6
Operation range Cooling Max. °CDB 46
    Min. °CDB -5
  Heating Min. °CWB -20
    Max. °CWB 15.5
Maximum number of connectable indoor units 64 (3)
Compressor Type   Hermetically sealed swing compressor
Weight Unit kg 104
Refrigerant Charge TCO2Eq 7.5
  GWP   2,087.5
  Charge kg 3.6
  Type   R-410A
Indoor index connection Min.   80
  Max.   176
Piping connections Liquid OD mm 9.52
    Type   Flare connection
  Gas OD mm 19.1
    Type   Braze connection
  Heat insulation   Both liquid and gas pipes
Sound power level Cooling Nom. dBA 70 (4)
Dimensions Unit Width mm 900
    Depth mm 320
    Height mm 1,345
Power supply Phase   3N~
  Name   Y1
  Frequency Hz 50
  Voltage V 380-415
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used.
  (3) - Actual number of units depends on the indoor unit type (VRV DX indoor, RA DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤130%).
  (4) - Sound power level is an absolute value that a sound source generates.
  (5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
  (6) - Sound values are measured in a semi-anechoic room.
  (7) - For detailed contents of standard accessories, see installation/operation manual
  (8) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
  (9) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current.
  (10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
  (11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
  (12) - TOCA means the total value of each OC set.
  (13) - FLA: nominal running current fan
  (14) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (15) - Maximum allowable voltage range variation between phases is 2%.