RXYSQ6T7Y1B9 |
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
51 (5)
|
Standard Accessories
|
Installation manual
|
Installation manual
|
|
Operation manual
|
Operation manual
|
|
Connection pipes
|
Connection pipes
|
Capacity range
|
HP
|
6
|
Operation range
|
Cooling
|
Max.
|
°CDB
|
46
|
|
|
Min.
|
°CDB
|
-5
|
|
Heating
|
Min.
|
°CWB
|
-20
|
|
|
Max.
|
°CWB
|
15.5
|
Maximum number of connectable indoor units
|
64 (3)
|
Compressor
|
Type
|
|
Hermetically sealed swing compressor
|
Weight
|
Unit
|
kg
|
104
|
Refrigerant
|
Charge
|
TCO2Eq
|
7.5
|
|
GWP
|
|
2,087.5
|
|
Charge
|
kg
|
3.6
|
|
Type
|
|
R-410A
|
Indoor index connection
|
Min.
|
|
80
|
|
Max.
|
|
176
|
Piping connections
|
Liquid
|
OD
|
mm
|
9.52
|
|
|
Type
|
|
Flare connection
|
|
Gas
|
OD
|
mm
|
19.1
|
|
|
Type
|
|
Braze connection
|
|
Heat insulation
|
|
Both liquid and gas pipes
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
70 (4)
|
Dimensions
|
Unit
|
Width
|
mm
|
900
|
|
|
Depth
|
mm
|
320
|
|
|
Height
|
mm
|
1,345
|
Power supply
|
Phase
|
|
3N~
|
|
Name
|
|
Y1
|
|
Frequency
|
Hz
|
50
|
|
Voltage
|
V
|
380-415
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used.
|
|
(3) - Actual number of units depends on the indoor unit type (VRV DX indoor, RA DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤130%).
|
|
(4) - Sound power level is an absolute value that a sound source generates.
|
|
(5) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
|
(6) - Sound values are measured in a semi-anechoic room.
|
|
(7) - For detailed contents of standard accessories, see installation/operation manual
|
|
(8) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
|
|
(9) - MSC means the maximum current during start up of the compressor. This unit uses only inverter compressors. Starting current is always ≤ max. running current.
|
|
(10) - MCA must be used to select the correct field wiring size. The MCA can be regarded as the maximum running current.
|
|
(11) - MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
|
|
(12) - TOCA means the total value of each OC set.
|
|
(13) - FLA: nominal running current fan
|
|
(14) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(15) - Maximum allowable voltage range variation between phases is 2%.
|