RXF20D5V1B RXF25D5V1B RXF35D5V1B RXF42D5V1B RXF50D5V1B RXF60D5V1B RXF71D5V1B
Dimensions Unit Height mm 550 550 550 550 734 734 734
    Width mm 658 658 658 658 870 870 870
    Depth mm 275 275 275 275 373 373 373
Weight Unit kg 24.0 24.0 24.0 28.0 46.0 50.0 50.0
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Operation range Cooling Ambient Min. °CDB -10 -10 -10 -10
      Max. °CDB 48 48 48 48
  Heating Ambient Min. °CWB -15 -15 -15 -15
      Max. °CWB 18 18 18 18
Sound pressure level Cooling High dBA 46.0 46.0 48.0 48.0
    Nom. dBA         47 49 52
  Heating High dBA 47.0 47.0 48.0 48.0
    Nom. dBA         49 49 52
Refrigerant Type   R-32 R-32 R-32 R-32 R-32 R-32 R-32
  Charge kg 0.450 0.450 0.550 0.750 0.90 1.15 1.15
  GWP   675.0 675.0 675.0 675.0 675 675 675
Piping connections Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
  Level difference IU - OU Max. m 12.0 12.0 12.0 12.0 20 20 20
Standard Accessories Installation manual 1 1 1 1 1 1 1
  Drain plug 1 1 1 1 1 1 1
  Refrigerant charge label 1 1 1 1 1 1 1
  Multilingual fluorinated greenhouse gases labels 1 1 1 1 1 1 1
  General safety precautions 1 1 1 1
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50
  Voltage V 220-240 220-240 220-240 220-240 220-240 220-240 220-240
Notes (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - Contains fluorinated greenhouse gases (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases
Standard Accessories Drain cap (1)         6 6 6
  Drain cap (2)         3 3 3