Specifications Table for RX-K1

RX20K2V1B1 RX25K2V1B1 RX35K2V1B1
Sound pressure level Heating High dBA 47 47 48
  Cooling High dBA 46 46 48
Standard Accessories Drain plug 1 1 1
  Installation manual 1 1 1
  Refrigerant charge label 1 1 1
Refrigerant Charge TCO2Eq 1.55 1.55 2.09
  GWP   2,087.5 2,087.5 2,087.5
  Charge kg 0.74 0.74 1.00
  Type   R-410A R-410A R-410A
Piping connections Level difference IU - OU Max. m 12.0 12.0 12.0
  Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
Dimensions Unit Width mm 658 658 658
    Depth mm 275 275 275
    Height mm 550 550 550
Compressor Type   Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor
Weight Unit kg 27 27 29
Power supply Phase   1~ 1~ 1~
  Frequency Hz 50 50 50
  Voltage V 220-240 220-240 220-240
Notes (1) - 220V (1) - 220V (1) - 220V
  (2) - 230V (2) - 230V (2) - 230V
  (3) - 240V (3) - 240V (3) - 240V
  (4) - Contains fluorinated greenhouse gases (4) - Contains fluorinated greenhouse gases (4) - Contains fluorinated greenhouse gases
  (5) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high. (5) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high. (5) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high.
  (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high. (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high. (6) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping length: 5m; level difference: 0m; indoor and outdoor unit fan speed: high.