RCV101001E RCV101002E RCV101527E RCV101528E RCV102001E RCV102002E RCV102528E RCV102527E RCV201001E RCV201002E RCV201527E RCV201528E RCV202002E RCV202527E RCV202528E RCV202001E
Refrigerant GWP   1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430 1,430
  Type   R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a R-134a
Refrigerating capacity High temperature R-134a Nom kW 0.6 0.6 0.6 0.6 1 1 1 1 1.4 1.4 1.4 1.4 2.3 2.3 2.3 2.3
Dimensions Unit Width mm 400 400 400 400 400 400 400 400 620 620 620 620 620 620 620 620
    Depth mm 435 435 435 435 435 435 435 435 435 435 435 435 435 435 435 435
    Height mm 735 735 735 735 735 735 735 735 735 735 735 735 735 735 735 735
Compressor Nominal power kW 0.25 0.25 0.25 0.25 0.37 0.37 0.37 0.37 0.46 0.46 0.46 0.46 0.55 0.55 0.55 0.55
  Type   Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating Hermetic Reciprocating
Weight Unit kg 49 50 49 50 52 53 53 52 77 78 77 78 80 79 80 79
Heating capacity R-134a Nom kW 0.7 0.7 0.7 0.7 1.05 1.05 1.05 1.05 1.4 1.4 1.4 1.4 1.75 1.75 1.75 1.75
Evaporator Air throw m 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2)
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
  Voltage V 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230
Notes (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C (1) - When normally running: +10°C / +30°C
  (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc.
  (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases (3) - Contains fluorinated greenhouse gases