LMDMD063AV3 | LMDMD070AV3 | LMDMD080AV3 | LMDMD110AV3 | |||||
---|---|---|---|---|---|---|---|---|
Refrigerant | GWP | 1,430 | 1,430 | 1,430 | 1,430 | |||
Type | R-134a | R-134a | R-134a | R-134a | ||||
Refrigerating capacity | Medium temperature | R-134a | Nom | kW | 1.112 (1) | 1.388 (1) | 1.768 (1) | 1.992 (1) |
Defrost | Hot gas | Hot gas | Hot gas | Hot gas | ||||
Power input | Medium temperature | R-134a | Nom | kW | 0.989 | 1.137 | 1.38 | 1.604 |
Dimensions | Unit | Width | mm | 537 | 537 | 832 | 832 | |
Depth | mm | 825 | 825 | 825 | 825 | |||
Height | mm | 705 | 705 | 695 | 695 | |||
Compressor | Type | Hermetic | Hermetic | Hermetic | Hermetic | |||
Weight | Unit | kg | 53 | 57 | 77 | 79 | ||
Evaporator | Air throw | m | 4 | 4 | 4 | 4 | ||
Defrost heaters | W | 1,320 | 1,580 | 1,669 | 2,117 | |||
Power supply | Phase | 1~ | 1~ | 1~ | 3~ | |||
Frequency | Hz | 50 | 50 | 50 | 50 | |||
Voltage | V | 230 | 230 | 230 | 400 | |||
Notes | (1) - When normally running: 0°C / +32°C | (1) - When normally running: 0°C / +32°C | (1) - When normally running: 0°C / +32°C | (1) - When normally running: 0°C / +32°C | ||||
(2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. | (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. | (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. | (2) - Use air throw as a base. Air throw is affected by many factors such as height of room, product storage, location of evaporator, etc. | |||||
(3) - Contains fluorinated greenhouse gases | (3) - Contains fluorinated greenhouse gases | (3) - Contains fluorinated greenhouse gases | (3) - Contains fluorinated greenhouse gases |