FXDQ15P3VE |
FXDQ20P3VE |
FXDQ25P3VE |
FXDQ32P3VE |
FXDQ40P3VE |
FXDQ50P3VE |
FXDQ63P3VE |
Refrigerant
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
Cooling capacity
|
Nom.
|
kW
|
1.7
|
2.2
|
2.8
|
3.6
|
4.5
|
5.6
|
7.1
|
Piping connections
|
Liquid
|
OD
|
mm
|
6.35
|
6.35
|
6.35
|
6.35
|
6.35
|
6.35
|
9.52
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
12.7
|
12.7
|
12.7
|
12.7
|
12.7
|
12.7
|
15.9
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Drain
|
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
VP20 (I.D. 20/O.D. 26)
|
Required ceiling void >
|
mm
|
240
|
240
|
240
|
240
|
240
|
240
|
240
|
Dimensions
|
Unit
|
Width
|
mm
|
750
|
750
|
750
|
750
|
950
|
950
|
1,150
|
|
|
Depth
|
mm
|
620
|
620
|
620
|
620
|
620
|
620
|
620
|
|
|
Height
|
mm
|
200
|
200
|
200
|
200
|
200
|
200
|
200
|
Casing
|
Material
|
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
Galvanised steel
|
|
Colour
|
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Not painted (galvanised)
|
Weight
|
Unit
|
kg
|
22
|
22
|
22
|
22
|
26
|
26
|
29
|
Fan
|
External static pressure - 50Hz
|
High
|
Pa
|
30
|
30
|
30
|
30
|
44
|
44
|
44
|
Drain-up height
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
Heating capacity
|
Nom.
|
kW
|
1.9
|
2.5
|
3.2
|
4.0
|
5.0
|
6.3
|
8.0
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Name
|
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
|
Frequency
|
Hz
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
|
Voltage
|
V
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
Notes
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m; level difference: 0m
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m; level difference: 0m
|
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
(4) - External static pressure is changeable to set by the remote control (from standard to high, see installation manual)
|
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(5) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
(6) - Maximum allowable voltage range variation between phases is 2%.
|
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
(7) - MCA/MFA: MCA = 1.25 x FLA
|
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
(8) - MFA ≤ 4 x FLA
|
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
(9) - Contains fluorinated greenhouse gases
|
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
(11) - Select wire size based on the value of MCA
|
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|
(12) - Next lower standard fuse rating minimum 15A
|