FUA100AVEB / RZASG100M7Y1B |
FUA100AVEB9 / RZASG100M7Y1B |
FUA125AVEB / RZASG125M7Y1B |
FUA125AVEB9 / RZASG125M7Y1B |
Cooling capacity
|
Nom.
|
kW
|
9.50 (1)
|
9.50 (1)
|
12.1 (1)
|
12.1 (1)
|
Space cooling
|
ηs,c
|
%
|
|
|
|
217
|
|
Annual energy consumption
|
kWh/a
|
570
|
570
|
1,322
|
1,322
|
|
Capacity
|
Pdesign
|
kW
|
9.50
|
9.50
|
12.1
|
12.1
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
6.00
|
6.00
|
6.00
|
6.00
|
|
Annual energy consumption
|
kWh/a
|
2,095
|
2,095
|
2,188
|
2,188
|
|
ηs,h
|
%
|
|
|
|
151
|
Heating capacity
|
Nom.
|
kW
|
10.8 (2)
|
10.8 (2)
|
13.5 (2)
|
13.5 (2)
|
Space cooling
|
SEER
|
|
5.83
|
5.83
|
5.49
|
5.49
|
|
Energy efficiency class
|
|
A+
|
A+
|
Space heating (Average climate)
|
SCOP/A
|
|
4.01
|
4.01
|
3.84
|
3.84
|
|
Energy efficiency class
|
|
A+
|
A+
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|