Specifications Table for FTXM-M / 2MXM-M

FTXM20M2V1B / FTXM20M2V1B / 2MXM40M2V1B FTXM20M2V1B / FTXM25M2V1B / 2MXM40M2V1B FTXM20M2V1B / FTXM35M2V1B / 2MXM40M2V1B FTXM25M2V1B / FTXM25M2V1B / 2MXM40M2V1B FTXM25M2V1B / FTXM35M2V1B / 2MXM40M2V1B FTXM20M2V1B / FTXM20M2V1B / 2MXM40M3V1B FTXM20M2V1B / FTXM25M2V1B / 2MXM40M3V1B FTXM20M2V1B / FTXM35M2V1B / 2MXM40M3V1B FTXM25M2V1B / FTXM25M2V1B / 2MXM40M3V1B FTXM25M2V1B / FTXM35M2V1B / 2MXM40M3V1B FTXM20M2V1B / FTXM20M2V1B / 2MXM50M2V1B FTXM20M2V1B / FTXM25M2V1B / 2MXM50M2V1B FTXM20M2V1B / FTXM35M2V1B / 2MXM50M2V1B FTXM20M2V1B / FTXM42M2V1B / 2MXM50M2V1B FTXM20M2V1B / FTXM50M2V1B / 2MXM50M2V1B FTXM25M2V1B / FTXM25M2V1B / 2MXM50M2V1B FTXM25M2V1B / FTXM35M2V1B / 2MXM50M2V1B FTXM25M2V1B / FTXM42M2V1B / 2MXM50M2V1B FTXM25M2V1B / FTXM50M2V1B / 2MXM50M2V1B FTXM35M2V1B / FTXM35M2V1B / 2MXM50M2V1B FTXM35M2V1B / FTXM42M2V1B / 2MXM50M2V1B FTXM35M2V1B / FTXM50M2V1B / 2MXM50M2V1B FTXM42M2V1B / FTXM42M2V1B / 2MXM50M2V1B
Cooling capacity Nom. kW 4.00 4.00 4.00 4.00 4.00           4.00 4.50 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
Space cooling SEER   8.53 8.50 8.19 8.36 8.11           8.71 8.67 8.54 8.54 8.51 8.53 8.56 8.57 8.52 8.57 8.60 8.52 8.56
  Annual energy consumption kWh/a 165 165 171 168 173           161 182 205 205 206 205 205 204 206 205 204 206 205
  Capacity Pdesign kW 4.00 4.00 4.00 4.00 4.00           4.00 4.50 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00 5.00
  Energy efficiency class   A+++ A+++ A++ A++ A++           A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Space heating (Average climate) Capacity Pdesign kW 3.20 3.20 3.20 3.20 3.20           4.00 4.10 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20 4.20
  SCOP/A   4.64 4.60 4.60 4.60 4.61           4.61 4.61 4.61 4.63 4.68 4.61 4.62 4.65 4.71 4.66 4.67 4.75 4.70
  Energy efficiency class   A++ A++ A++ A++ A++           A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.6 2.7 2.8 2.7 2.8           3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4
  Annual energy consumption kWh/a 966 973 974 974 971           1,214 1,244 1,275 1,268 1,255 1,275 1,272 1,265 1,249 1,262 1,258 1,238 1,251
Nominal efficiency Annual energy consumption kWh 486 481 477 479 472           471 535 619 615 609 624 616 612 606 609 604 599 601
  EER   4.12 4.16 4.20 4.18 4.24           4.25 4.21 4.04 4.07 4.11 4.01 4.06 4.09 4.13 4.11 4.14 4.18 4.16
  COP   4.28 4.32 4.41 4.37 4.46           4.09 4.10 4.12 4.13 4.15 4.08 4.05 4.03 3.98 4.01 4.00 3.94 3.98
  Energy labeling Directive Cooling   A A A A A           A A A A A A A A A A A A A
    Heating   A A A A A           A A A A A A A A A A A A A
Heating capacity Nom. kW 4.20 4.20 4.20 4.20 4.20                     5.60
Cooling capacity Nom. kW           4.0 4.0 4.0 4.0 4.0
Heating capacity Nom. kW           4.20 4.20 4.20 4.20 4.20
Nominal efficiency EER             4.12 4.16 4.20 4.18 4.24
  COP             4.28 4.32 4.41 4.37 4.46
  Annual energy consumption kWh           486 481 477 479 472
  Energy labeling Directive Cooling             A A A A A
    Heating             A A A A A
Space cooling Energy efficiency class             A+++ A+++ A++ A++ A++
  Capacity Pdesign kW           4.00 4.00 4.00 4.00 4.00
  SEER             8.53 8.50 8.19 8.36 8.11
  Annual energy consumption kWh/a           165 165 171 168 173
Space heating (Average climate) Energy efficiency class             A++ A++ A++ A++ A++
  Capacity Pdesign kW           3.20 3.20 3.20 3.20 3.20
  SCOP/A             4.64 4.60 4.60 4.60 4.61
  Pdh Heating capacity at -10° kW           3 3 3 3 3
  Annual energy consumption kWh/a           966 973 974 974 971
Energy Efficiency Range           A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D
Notes           (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series. Eurovent 2015 tolerances are used.
            (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Heating capacity Min. kW                     5.20 5.60 5.60 5.60 5.60   5.60 5.60 5.60 5.60 5.60 5.60 5.60
Notes                     (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only