Specifications Table for FFA-A9 / RZAG-MY1

FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / RZAG71M7Y1B FFA35A2VEB9 / FFA35A2VEB9 / RZAG71M7Y1B FFA50A2VEB9 / FFA50A2VEB9 / RZAG71M7Y1B FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / RZAG100M7Y1B FFA35A2VEB9 / FFA35A2VEB9 / FFA35A2VEB9 / RZAG100M7Y1B FFA50A2VEB9 / FFA50A2VEB9 / FFA50A2VEB9 / RZAG100M7Y1B FFA50A2VEB9 / FFA50A2VEB9 / RZAG100M7Y1B
Cooling capacity Nom. kW 6.80 (1) 6.80 (1) 6.80 (1) 9.50 (1) 9.50 (1) 9.50 (1) 9.50 (1)
Space cooling SEER   7.17 7.11 7.31 8.23 7.66 7.56 7.03
  Annual energy consumption kWh/a 332 335 326 404 434 440 473
  Capacity Pdesign kW 6.80 6.80 6.80 9.50 9.50 9.50 9.50
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++
Space heating (Average climate) Capacity Pdesign kW 4.70 4.70 4.70 7.80 7.80 7.80 7.80
  SCOP/A   4.03 4.22 4.18 4.34 4.08 4.44 4.17
  Energy efficiency class   A+ A+ A+ A+ A+ A+ A+
  Annual energy consumption kWh/a 1,633 1,559 1,574 2,516 2,677 2,460 2,619
Heating capacity Nom. kW 7.50 (2) 7.50 (2) 7.50 (2) 10.8 (2) 10.8 (2) 10.8 (2) 10.8 (2)
Notes (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
    (3) - See separate drawing for operation range     (3) - See separate drawing for operation range   (3) - See separate drawing for operation range
    (4) - See separate drawing for electrical data     (4) - See separate drawing for electrical data   (4) - See separate drawing for electrical data