Specifications Table for FCQHG-F / RZQG-L(8)Y1

FCQHG100FVEB / RZQG71L8Y1B FCQHG71FVEB / RZQG71L8Y1B FCQHG100FVEB / RZQG100L8Y1B FCQHG140FVEB / RZQG100L8Y1B FCQHG71FVEB / FCQHG71FVEB / RZQG100L8Y1B FCQHG125FVEB / RZQG125L8Y1B FCQHG140FVEB / RZQG125L8Y1B FCQHG71FVEB / FCQHG71FVEB / RZQG125L8Y1B FCQHG140FVEB / RZQG140L7Y1B
Cooling capacity Nom. kW   6.80 9.5     12.0     13.4
Space cooling SEER   7.00 6.91 7 7.00 5.10 6.61 6.61 5.10
  Annual energy consumption kWh/a 340 345 475 475 652 636 636 824
  Capacity Pdesign kW 6.80 6.80 9.5 9.50 9.50 12 12.00 12.00
  Energy efficiency class   A++ A++ A++ A++ B A++ A++ B
Space heating (Average climate) Capacity Pdesign kW 7.60 7.60 11.3 11.30 11.30 12.66 12.66 12.71
  SCOP/A   4.54 4.54 4.8 4.80 3.80 4.63 4.63 3.80
  Energy efficiency class   A+ A+ A++ A++ A A++ A++ A
  Annual energy consumption kWh/a 2,344 2,344 3,296 3,296 4,164 3,829 3,829 4,683
Nominal efficiency EER     4.09 4.42     4.00     3.35
  Annual energy consumption kWh   830 1,075     1,500
  COP     4.80 4.99     4.40     4.12
  Energy labeling Directive Cooling     A A     A
    Heating     A A     A
Heating capacity Nom. kW   7.5 10.8     13.5     15.5
Notes   (1) - Annual energy consumption is according to Energy labeling directive 2002/31/EC (1) - EER/COP according to Eurovent 2012, for use outside EU only     (1) - EER/COP according to Eurovent 2012, for use outside EU only     (1) - EER/COP according to Eurovent 2012, for use outside EU only
    (2) - SEER and SCOP are according to EN 14825 (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load     (2) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load