| FCAHG71HVEB / RZQSG71L3V1B | FCAHG100HVEB / RZQSG100L9V1B | FCAHG125HVEB / RZQSG125L9V1B | FCAHG140HVEB / RZQSG140L9V1B | ||||
|---|---|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 6.80 | 9.50 | 12.00 | 13.40 | |
| Space cooling | SEER | 6.50 | 6.70 | 5.40 | 6.61 | ||
| Annual energy consumption | kWh/a | 367 | 497 | 778 | 1,215 | ||
| Capacity | Pdesign | kW | 6.80 | 9.50 | 12.00 | 13.40 | |
| Energy efficiency class | A++ | A++ | A | ||||
| Space heating (Average climate) | Capacity | Pdesign | kW | 7.60 | 8.03 | 8.03 | 11.78 |
| SCOP/A | 4.15 | 4.30 | 4.10 | 4.29 | |||
| Energy efficiency class | A+ | A+ | A+ | ||||
| Annual energy consumption | kWh/a | 2,563 | 2,615 | 2,742 | 3,843 | ||
| Nominal efficiency | EER | 3.50 | 3.70 | 3.12 | 3.11 | ||
| Annual energy consumption | kWh | 971 | 1,284 | 1,923 | |||
| COP | 4.10 | 4.30 | 3.75 | 3.61 | |||
| Energy labeling Directive | Cooling | A | A | B | |||
| Heating | A | A | A | ||||
| Heating capacity | Nom. | kW | 7.50 | 10.80 | 13.50 | 15.50 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||