| EWWQ014KBW1N | EWWQ025KBW1N | EWWQ033KBW1N | EWWQ049KBW1N | EWWQ064KBW1N | EWWQ098KBW1N | EWWQ113KBW1N | EWWQ128KBW1N | EWWQ147KBW1N | EWWQ162KBW1N | EWWQ177KBW1N | EWWQ192KBW1N | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sound pressure level | Cooling | Nom. | dBA | 55.71 | 59.71 | 61.71 | 56.9 | 60.9 | 61.9 | 62.9 | ||||||
| Refrigerant | Circuits | Quantity | 4 | 4 | 4 | 6 | 6 | 6 | 6 | |||||||
| Charge | kg | 9.4 | 10.2 | 11.2 | 13.8 | 14.8 | 15.8 | 16.8 | ||||||||
| Type | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | R-410A | |||||||||
| Cooling capacity | Nom. | kW | 94 | 108 | 122 | 142 | 155 | 169 | 183 | |||||||
| Power input | Cooling | Nom. | kW | 22.7 | 25.8 | 28.9 | 33.9 | 37 | 40.1 | 43.2 | ||||||
| Sound power level | Cooling | Nom. | dBA | 71 | 75 | 77 | 73 | 77 | 78 | 79 | ||||||
| Dimensions | Unit | Width | mm | 600 | 600 | 600 | 600 | 600 | 600 | 600 | ||||||
| Depth | mm | 1,200 | 1,200 | 1,200 | 1,200 | 1,200 | 1,200 | 1,200 | ||||||||
| Height | mm | 1,200 | 1,200 | 1,200 | 1,800 | 1,800 | 1,800 | 1,800 | ||||||||
| Compressor | Type | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | ||||||||
| Quantity | 4 | 4 | 4 | 6 | 6 | 6 | 6 | |||||||||
| Water heat exchanger - condenser | Type | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | ||||||||
| Water flow rate | Nom. | l/s | 5.57 | 6.39 | 7.21 | 8.35 | 9.17 | 10 | 10.8 | |||||||
| Capacity control | Minimum capacity | % | 25 | 25 | 25 | 16 | 16 | 16 | 16 | |||||||
| Weight | Operation weight | kg | 640 | 673 | 707 | 960 | 993 | 1,026 | 1,060 | |||||||
| Unit | kg | 620 | 650 | 680 | 930 | 960 | 990 | 1,020 | ||||||||
| Water heat exchanger - evaporator | Water flow rate | Nom. | l/s | 4.5 | 5.2 | 5.8 | 6.8 | 7.4 | 8.1 | 8.8 | ||||||
| Type | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | |||||||||
| Water volume | l | 9 | 10 | 12 | 14 | 15 | 16 | 18 | ||||||||
| EER | 4.209 | 4.177 | 4.164 | 4.127 | 4.182 | 4.17 | 4.19 | 4.22 | 4.18 | 4.2 | 4.22 | 4.24 | ||||
| ESEER | 4.52 | 4.58 | 4.72 | 4.56 | 4.71 | 4.65 | 4.64 | 4.66 | 4.7 | 4.69 | 4.70 | 4.71 | ||||
| Power supply | Phase | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | 3~ | ||||||||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | 50 | 50 | ||||||||
| Voltage | V | 400 | 400 | 400 | 400 | 400 | 400 | 400 | ||||||||
| Notes | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | (1) - Nominal cooling capacities are based on the following conditions. Evaporator: 12°C/7°C; condenser: 30°C/35°C | ||||
| (2) - The nominal sound power level is measured according to ISO9614 | (2) - The nominal sound power level is measured according to ISO9614 | (2) - The nominal sound power level is measured according to ISO9614 | (2) - The nominal sound power level is measured according to ISO9614 | (2) - The nominal sound power level is measured according to ISO9614 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | (2) - Sound level data are measured at entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation; standard: ISO3744 | |||||
| (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | (3) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels. | |||||
| (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | (4) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%. | |||||
| (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | (5) - Electrical data referred to standard unit without options, refer to name plate data. | |||||
| Cooling capacity | Nom. | kW | 13.25 | 23.9 | 30.4 | 47.15 | 60.98 | |||||||||
| Capacity control | Method | Fixed | Fixed | Fixed | Fixed | Fixed | ||||||||||
| Minimum capacity | % | 100 | 100 | 100 | 50 | 50 | ||||||||||
| Power input | Cooling | Nom. | kW | 3.15 | 5.72 | 7.3 | 11.42 | 14.58 | ||||||||
| Dimensions | Unit | Depth | mm | 600 | 600 | 600 | 1200 | 1200 | ||||||||
| Height | mm | 600 | 600 | 600 | 600 | 600 | ||||||||||
| Width | mm | 600 | 600 | 600 | 600 | 600 | ||||||||||
| Weight | Unit | kg | 120 | 170 | 175 | 310 | 340 | |||||||||
| Operation weight | kg | 123 | 175 | 182 | 320 | 353 | ||||||||||
| Water heat exchanger - evaporator | Type | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | ||||||||||
| Water volume | l | 1.23 | 1.93 | 2.68 | 4.5 | 5.93 | ||||||||||
| Water flow rate | Nom. | l/s | 0.64 | 1.15 | 1.46 | 2.26 | 2.92 | |||||||||
| Water heat exchanger - condenser | Type | Brazed plate | Brazed plate | Brazed plate | Brazed plate | Brazed plate | ||||||||||
| Water flow rate | Nom. | l/s | 0.78 | 1.41 | 1.83 | 2.78 | 3.61 | |||||||||
| Compressor | Type | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | Scroll compressor | ||||||||||
| Quantity | 1 | 1 | 1 | 2 | 2 | |||||||||||
| Sound power level | Cooling | Nom. | dBA | 64 | 64 | 71 | 67 | 74 | ||||||||
| Sound pressure level | Cooling | Nom. | dBA | 50 | 50 | 57 | 53 | 60 | ||||||||
| Refrigerant | Type | R-410A | R-410A | R-410A | R-410A | R-410A | ||||||||||
| Charge | kg | 1.2 | 2 | 3.1 | 4.6 | 5.6 | ||||||||||
| Circuits | Quantity | 1 | 1 | 1 | 2 | 2 | ||||||||||
| Space heating | Average climate water outlet 35°C | General | Seasonal space heating eff. class | A+++ | A+++ | A+++ | A+++ | A+++ | ||||||||
| Energy Efficiency Range | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | Space Heating A+++ ~ D, Water Heating A+ ~ F | |||||||||||
| Power supply | Name | W1 | W1 | W1 | W1 | W1 | ||||||||||
| Phase | 3~ | 3~ | 3~ | 3~ | 3~ | |||||||||||
| Frequency | Hz | 50 | 50 | 50 | 50 | 50 | ||||||||||
| Voltage | V | 400 | 400 | 400 | 400 | 400 | ||||||||||