EWWQ090G-SS |
EWWQ100G-SS |
EWWQ120G-SS |
EWWQ130G-SS |
EWWQ150G-SS |
EWWQ170G-SS |
EWWQ190G-SS |
EWWQ210G-SS |
EWWQ240G-SS |
EWWQ300G-SS |
EWWQ360G-SS |
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
64
|
67
|
69
|
70
|
72
|
72
|
72
|
74
|
76
|
76
|
77
|
Refrigerant
|
Circuits
|
Quantity
|
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
GWP
|
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
2,087.5
|
|
Charge
|
kg
|
10
|
10
|
11
|
11
|
12
|
12
|
15
|
16
|
17
|
19
|
20
|
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
Operation range
|
Condenser
|
Cooling
|
Min.
|
°CDB
|
25
|
|
|
|
Max.
|
°CDB
|
55
|
|
Evaporator
|
Cooling
|
Min.
|
°CDB
|
-10
|
|
|
|
Max.
|
°CDB
|
15
|
Cooling capacity
|
Nom.
|
kW
|
93.7
|
105.6
|
119
|
135.9
|
150
|
172.1
|
193.8
|
220.7
|
246.1
|
314.3
|
370.4
|
Power input
|
Cooling
|
Nom.
|
kW
|
21.3
|
24
|
26.9
|
30.5
|
33.9
|
38.9
|
43.8
|
50.74
|
56.1
|
70.2
|
84
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
80
|
83
|
85
|
87
|
88
|
88
|
88
|
90
|
92
|
93
|
93
|
Refrigerant charge
|
Refrigerant charge-=-Per circuit-=-TCO2Eq
|
TCO2Eq
|
20.88
|
20.88
|
22.96
|
22.96
|
25.05
|
25.05
|
31.31
|
33.40
|
35.49
|
39.66
|
41.75
|
Dimensions
|
Unit
|
Width
|
mm
|
928
|
928
|
928
|
928
|
928
|
928
|
928
|
928
|
928
|
928
|
928
|
|
|
Depth
|
mm
|
2,432
|
2,432
|
2,264
|
2,264
|
2,264
|
2,432
|
2,432
|
2,432
|
2,432
|
2,432
|
2,432
|
|
|
Height
|
mm
|
1,066
|
1,066
|
1,066
|
1,066
|
1,066
|
1,066
|
1,066
|
1,066
|
1,066
|
1,186
|
1,186
|
Compressor
|
Type
|
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
Scroll compressor
|
|
Quantity
|
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
Water heat exchanger - condenser
|
Type
|
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
|
Water flow rate
|
Nom.
|
l/s
|
5.52
|
6.23
|
7.05
|
8.04
|
8.87
|
10.17
|
11.43
|
13.02
|
14.53
|
18.46
|
21.81
|
Capacity control
|
Minimum capacity
|
%
|
50
|
43
|
50
|
44
|
50
|
45
|
50
|
43
|
50
|
40
|
50
|
|
Method
|
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Fixed
|
Weight
|
Operation weight
|
kg
|
554.9
|
652.4
|
781.6
|
821.4
|
859
|
901.4
|
945.9
|
1,009.6
|
1,023.2
|
1,194.7
|
1,311.1
|
|
Unit
|
kg
|
516
|
606
|
728
|
762
|
795
|
832
|
871
|
921
|
934
|
1,083
|
1,181
|
Water heat exchanger - evaporator
|
Water flow rate
|
Nom.
|
l/s
|
4.5
|
5.07
|
5.7
|
6.51
|
7.18
|
8.24
|
9.28
|
10.57
|
11.79
|
15.06
|
17.74
|
|
Type
|
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
Plate heat exchanger
|
|
Water volume
|
l
|
6
|
8
|
8
|
10
|
12
|
13
|
15
|
17
|
17
|
27
|
34
|
EER
|
4.399
|
4.4
|
4.424
|
4.456
|
4.425
|
4.424
|
4.425
|
4.349
|
4.387
|
4.477
|
4.41
|
ESEER
|
5.51
|
5.52
|
5.51
|
5.53
|
5.51
|
5.53
|
5.52
|
5.52
|
5.52
|
5.52
|
5.52
|
Power supply
|
Phase
|
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
Notes
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
(1) - Cooling: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; entering condenser water temp. 30°C; leaving condenser water temp. 35°C; full load operation.
|
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
(2) - Heating capacity, unit power input and COP are based on the following conditions: evaporator 5/10°C; condensor 40/45°C, unit at full load operation
|
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
(3) - Sound power level (at standard conditions) is measured in accordance with ISO9614 and Eurovent 8/1 for Eurovent certified units
|
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
(4) - Fluid: Water
|
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(5) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(6) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(7) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
(8) - Maximum starting current: starting current of biggest compressor + current of the compressor at 75% maximum load
|
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
(9) - Nominal current cooling mode is referred to the following conditions: evaporator 12/7°C; condenser 30/35°C; compressors current
|
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
(10) - Maximum running current is based on max compressor absorbed current in its envelope
|
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(11) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|
(12) - Maximum current for wires sizing: compressor full load ampere x 1.1
|