EWAD190TZPRB1 |
EWAD220TZPRB1 |
EWAD240TZPRB1 |
EWAD290TZPRB1 |
EWAD300TZPRB1 |
EWAD350TZPRB2 |
EWAD420TZPRB2 |
EWAD495TZPRB2 |
EWAD550TZPRB2 |
EWAD620TZPRB2 |
EWAD720TZPRB2 |
EWAD820TZPRB2 |
EWAD950TZPRB2 |
Cooling capacity
|
Nom.
|
kW
|
187.3
|
218.2
|
246.8
|
279.2
|
317.2
|
382.3
|
436.9
|
505.5
|
543
|
620
|
717
|
833
|
950
|
Capacity control
|
Minimum capacity
|
%
|
34
|
29
|
34
|
29
|
27
|
19
|
20
|
17
|
10
|
10
|
10
|
10
|
10
|
Power input
|
Cooling
|
Nom.
|
kW
|
50.48
|
60.72
|
68.74
|
83.42
|
95.88
|
105.1
|
125.3
|
139.7
|
151.3
|
178.5
|
182.2
|
220.2
|
252.4
|
EER
|
3.71
|
3.594
|
3.59
|
3.347
|
3.308
|
3.637
|
3.486
|
3.618
|
3.59
|
3.473
|
3.935
|
3.783
|
3.764
|
IPLV
|
6.49
|
6.35
|
6.23
|
6.07
|
6.04
|
6.3
|
6.27
|
6.47
|
6.53
|
6.47
|
6.73
|
6.6
|
6.64
|
SEER
|
5.29
|
5.38
|
5.34
|
5.25
|
5.38
|
5.28
|
5.33
|
5.6
|
5.53
|
5.57
|
6.29
|
6.31
|
6.35
|
Dimensions
|
Unit
|
Depth
|
mm
|
4,083
|
4,083
|
4,083
|
4,083
|
4,983
|
5,883
|
6,783
|
6,783
|
8,820
|
9,591
|
9,591
|
10,461
|
11,233
|
|
|
Height
|
mm
|
2,483
|
2,483
|
2,483
|
2,483
|
2,483
|
2,483
|
2,483
|
2,483
|
2,482
|
2,482
|
2,482
|
2,482
|
2,482
|
|
|
Width
|
mm
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
2,258
|
Weight
|
Operation weight
|
kg
|
2,908
|
2,908
|
2,919
|
2,920
|
3,170
|
5,190
|
5,524
|
5,532
|
6,927
|
6,955
|
8,220
|
8,513
|
8,810
|
|
Unit
|
kg
|
2,858
|
2,858
|
2,869
|
2,870
|
3,120
|
4,935
|
5,269
|
5,277
|
6,677
|
6,705
|
7,970
|
8,263
|
8,560
|
Casing
|
Colour
|
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
Ivory white
|
|
Material
|
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Galvanized and painted steel sheet
|
Air heat exchanger
|
Type
|
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Microchannel
|
Fan
|
Quantity
|
|
8
|
8
|
8
|
8
|
10
|
12
|
14
|
16
|
18
|
20
|
20
|
22
|
24
|
|
Type
|
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Direct propeller
|
Fan motor
|
Drive
|
|
Brushless
|
Brushless
|
Brushless
|
Brushless
|
Brushless
|
Brushless
|
Brushless
|
Brushless
|
VFD driven
|
VFD driven
|
Brushless
|
Brushless
|
Brushless
|
Compressor
|
Quantity
|
|
1
|
1
|
1
|
1
|
1
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
|
Type
|
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
Inverter driven single screw compressor
|
|
Starting method
|
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Inverter driven
|
Operation range
|
Air side
|
Cooling
|
Min.
|
°CDB
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
-18
|
|
|
|
Max.
|
°CDB
|
52
|
52
|
52
|
52
|
52
|
52
|
52
|
52
|
52
|
52
|
55
|
55
|
55
|
|
Water side
|
Evaporator
|
Min.
|
°CDB
|
-8
|
-8
|
-8
|
-8
|
-8
|
-8
|
-8
|
-8
|
-8
|
-8
|
-15
|
-15
|
-15
|
|
|
|
Max.
|
°CDB
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
18
|
20
|
20
|
20
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
87
|
88
|
87
|
88
|
88
|
89
|
90
|
90
|
94
|
95
|
95
|
95
|
95
|
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
67
|
68
|
67
|
68
|
68
|
68
|
68
|
69
|
73
|
73
|
73
|
73
|
73
|
Refrigerant
|
Type
|
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
R-134a
|
|
GWP
|
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
1,430
|
|
Charge
|
kg
|
49
|
49
|
50
|
51
|
58
|
77
|
86
|
94
|
105
|
114
|
130
|
143
|
156
|
|
Circuits
|
Quantity
|
|
1
|
1
|
1
|
1
|
1
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
Piping connections
|
Evaporator water inlet/outlet (OD)
|
|
3"
|
3"
|
4"
|
4"
|
4"
|
6”
|
6”
|
6”
|
168.3 mm
|
168.3 mm
|
219.1mm
|
219.1mm
|
219.1mm
|
Power supply
|
Phase
|
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
3~
|
|
Frequency
|
Hz
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Voltage
|
V
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
400
|
|
Voltage range
|
Min.
|
%
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
-10
|
|
|
Max.
|
%
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
Unit
|
Starting current
|
Max
|
A
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
0
|
|
Running current
|
Cooling
|
Nom.
|
A
|
101
|
104
|
172
|
177
|
177
|
209
|
212
|
347
|
259
|
300
|
317
|
377
|
426
|
|
|
Max
|
A
|
126
|
144
|
162
|
188
|
218
|
246
|
285
|
324
|
352
|
436
|
437
|
512
|
577
|
|
Max unit current for wires sizing
|
A
|
136
|
150
|
176
|
205
|
238
|
267
|
298
|
352
|
383
|
476
|
475
|
557
|
629
|
Notes
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
(1) - All the performances (Cooling capacity, unit power input in cooling and EER) are based on the following conditions: evaporator 12.0/7.0°C; ambient 35.0°C, unit at full load operation, operating fluid: water, fouling factor = 0
|
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
(2) - The value refers to the pressure drop in the evaporator only
|
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
(3) - Sound power level (referred to evaporator 12/7°C, ambient 35°C full load operation) are measured in accordance with ISO 9614 and Eurovent 8/1
|
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
(4) - The sound pressure level is measured via a microphone at 1m distance of the unit.
|
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
(5) - The minimum capacity indicated is referred to unit operating at standard Eurovent condition
|
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
(6) - Dimensions and weights are for indication only and are not considered binding. Before designing the installation, consult the official drawings available from the factory on request.
|
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
(7) - All data refers to the standard unit without options.
|
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
(8) - Allowed voltage tolerance ± 10%. Voltage unbalance between phases must be within ± 3%.
|
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
(9) - Maximum starting current: starting current of biggest compressor + current of the other compressors at maximum load + fans current at maximum load. In case of inverter driven units, no inrush current at start up is experienced.
|
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
(10) - Nominal current in cooling mode: entering evaporator water temp. 12°C; leaving evaporator water temp. 7°C; ambient air temp. 35°C. Compressor + fans current.
|
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
(11) - Maximum running current is based on max compressor absorbed current in its envelope and max fans absorbed current
|
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
(12) - Maximum unit current for wires sizing is based on minimum allowed voltage.
|
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
(13) - Maximum current for wires sizing: (compressors full load ampere + fans current) x 1.1
|
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
(14) - For the electrical data of the hydronic kit refer to "Options technical data" part in the data book
|
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
(15) - All data are subject to change without notice. Please refer to the unit nameplate data.
|
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
(16) - For more details on the operating limits please refer to the Chiller Selection Software (CSS).
|
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
(17) - The sound pressure level is calculated from the sound power level and is for information only and not considered binding
|
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
(18) - Fluid: Water
|
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|
(19) - Equipment contains fluorinated greenhouse gases. Actual refrigerant charge depends on the final unit construction, details can be found on the unit labels.
|