Specifications Table for ETSHB16E / EPRA014-018DW

ETSHB16P30EF / EPRA14DAW1 ETSHB16P30EF / EPRA16DAW1 ETSHB16P30EF / EPRA18DAW1 ETSHB16P50EF / EPRA14DAW1 ETSHB16P50EF / EPRA16DAW1 ETSHB16P50EF / EPRA18DAW1
Domestic hot water heating General Declared load profile   L L L XL XL XL
  Average climate Water heating energy efficiency class   A+ A+ A+ A+ A+ A+
COP 4.79 (2) 5.00 (2) 5.00 (2) 4.79 (2) 5.00 (2) 5.00 (2)
Indoor unit ETSHB16P30EF ETSHB16P30EF ETSHB16P30EF ETSHB16P50EF ETSHB16P50EF ETSHB16P50EF
Space heating Average climate water outlet 35°C General ηs (Seasonal space heating efficiency) % 186 186 186 186 186 186
      Seasonal space heating eff. class   A+++ A+++ A+++ A+++ A+++ A+++
      SCOP   4.71 4.71 4.71 4.71 4.71 4.71
  Average climate water outlet 55°C General Seasonal space heating eff. class   A++ A++ A++ A++ A++ A++
      ηs (Seasonal space heating efficiency) % 140 140 140 140 140 140
      SCOP   3.57 3.57 3.57 3.57 3.57 3.57
Heating capacity Nom. kW 5.90 (2) 9.00 (2) 9.00 (2) 5.90 (2) 9.00 (2) 9.00 (2)
  Min. kW 3.70 (1) 3.96 (1) 4.40 (1) 3.70 (1) 3.96 (1) 4.40 (1)
  Max. kW 9.75 (1) 10.44 (1) 11.60 (1) 9.75 (1) 10.44 (1) 11.60 (1)
Power input Heating Max. kW 2.17 (5) 2.32 (5) 2.58 (5) 2.17 (5) 2.32 (5) 2.58 (5)
    Min. kW 0.84 (5) 0.90 (5) 1.00 (5) 0.84 (5) 0.90 (5) 1.00 (5)
    Nom. kW 1.23 (2) 1.80 (2) 1.80 (2) 1.23 (2) 1.80 (2) 1.80 (2)
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511