Specifications Table for ETBX16E9W / EPRA014-018DV

ETBX16EF9W / EPRA14DAV3 ETBX16EF9W / EPRA16DAV3 ETBX16EF9W / EPRA18DAV3
COP 4.67 (2) 5.00 (2) 5.00 (2)
Space heating Average climate water outlet 35°C General ηs (Seasonal space heating efficiency) %   180 180
      Seasonal space heating eff. class   A+++ A+++ A+++
      SCOP   4.57 4.57 4.57
  Average climate water outlet 55°C General Seasonal space heating eff. class   A++ A++ A++
      ηs (Seasonal space heating efficiency) %   142 142
      SCOP   3.62 3.62 3.62
Cooling capacity Nom. kW 10.6 (3), 6.90 (4) 11.5 (3), 7.88 (4) 12.5 (3), 8.86 (4)
EER 4.13 (3), 2.70 (4) 4.11 (3), 2.69 (4) 4.09 (3), 2.68 (4)
Heating capacity Nom. kW 5.69 (2) 9.00 (2) 9.00 (2)
  Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
  Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
    Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
    Nom. kW 1.22 (2) 1.80 (2) 1.80 (2)
  Cooling Nom. kW 2.55 (3), 2.56 (4) 2.80 (3), 2.93 (4) 3.05 (3), 3.31 (4)
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (3) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (4) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
  (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed