Specifications Table for ETBX12E9W / EPRA08-12EV

ETBX12EF9W / EPRA08EAV3 ETBX12EF9W / EPRA10EAV3 ETBX12EF9W / EPRA12EAV3
Indoor unit ETBX12EF9W ETBX12EF9W ETBX12EF9W
Heating capacity Min. kW 3.44 (1) 3.44 (1) 3.44 (1)
  Nom. kW 6.17 (2) 6.17 (2) 6.17 (2)
  Max. kW 7.95 (1) 9.25 (1) 9.97 (1)
Cooling capacity Nom. kW 6.81 (3), 6.47 (4) 7.97 (3), 6.47 (4) 8.62 (3), 6.47 (4)
Power input Heating Min. kW 0.72 (5) 0.72 (5) 0.72 (5)
    Nom. kW 1.25 (2) 1.25 (2) 1.25 (2)
    Max. kW 1.69 (5) 2.04 (5) 2.28 (5)
  Cooling Nom. kW 2.15 (3), 1.16 (4) 2.66 (3), 1.16 (4) 2.96 (3), 1.16 (4)
COP 4.92 (2) 4.92 (2) 4.92 (2)
EER 3.17 (3), 5.56 (4) 3.00 (3), 5.56 (4) 2.91 (3), 5.56 (4)
Space heating Average climate water outlet 55°C General SCOP   3.47 3.48 3.48
      Seasonal space heating eff. class   A++ A++ A++
  Average climate water outlet 35°C General SCOP   4.79 4.82 4.82
      Seasonal space heating eff. class   A+++ A+++ A+++
Notes (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB (3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
  (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB (4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
  (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
  (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147. (6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed