ETBX12EF9W / EPRA08EAV3 |
ETBX12EF9W / EPRA10EAV3 |
ETBX12EF9W / EPRA12EAV3 |
Indoor unit
|
ETBX12EF9W
|
ETBX12EF9W
|
ETBX12EF9W
|
Heating capacity
|
Min.
|
kW
|
3.44 (1)
|
3.44 (1)
|
3.44 (1)
|
|
Nom.
|
kW
|
6.17 (2)
|
6.17 (2)
|
6.17 (2)
|
|
Max.
|
kW
|
7.95 (1)
|
9.25 (1)
|
9.97 (1)
|
Cooling capacity
|
Nom.
|
kW
|
6.81 (3), 6.47 (4)
|
7.97 (3), 6.47 (4)
|
8.62 (3), 6.47 (4)
|
Power input
|
Heating
|
Min.
|
kW
|
0.72 (5)
|
0.72 (5)
|
0.72 (5)
|
|
|
Nom.
|
kW
|
1.25 (2)
|
1.25 (2)
|
1.25 (2)
|
|
|
Max.
|
kW
|
1.69 (5)
|
2.04 (5)
|
2.28 (5)
|
|
Cooling
|
Nom.
|
kW
|
2.15 (3), 1.16 (4)
|
2.66 (3), 1.16 (4)
|
2.96 (3), 1.16 (4)
|
COP
|
4.92 (2)
|
4.92 (2)
|
4.92 (2)
|
EER
|
3.17 (3), 5.56 (4)
|
3.00 (3), 5.56 (4)
|
2.91 (3), 5.56 (4)
|
Space heating
|
Average climate water outlet 55°C
|
General
|
SCOP
|
|
3.47
|
3.48
|
3.48
|
|
|
|
Seasonal space heating eff. class
|
|
A++
|
A++
|
A++
|
|
Average climate water outlet 35°C
|
General
|
SCOP
|
|
4.79
|
4.82
|
4.82
|
|
|
|
Seasonal space heating eff. class
|
|
A+++
|
A+++
|
A+++
|
Notes
|
(1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
(1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
(1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
|
|
(2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(2) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
(3) - Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB
|
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
(4) - Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB
|
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
(5) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
|
|
(6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
|
(6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
|
(6) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
|
|
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed
|
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed
|
(7) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed
|