Specifications Table for ERSQ-AV1

ERSQ011AAV1 ERSQ014AAV1 ERSQ016AAV1
Sound pressure level Heating Nom. dBA 52 53 55
Standard Accessories Installation manual 1 1 1
Refrigerant GWP   2,087.5 2,087.5 2,087.5
  Charge kg 4.5 4.5 4.5
  Type   R-410A R-410A R-410A
Operation range Heating Max. °CWB 20 20 20
    Min. °CWB -20 -20 -20
  Domestic hot water Min. °CDB -20 -20 -20
    Max. °CDB 35 35 35
Piping connections Heat insulation   Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes
  Liquid OD mm 9.52 9.52 9.52
  Gas OD mm 15.9 15.9 15.9
  Drain OD mm 26x3 26x3 26x3
  Level difference IU - OU Max. m 30 30 30
Sound power level Heating Nom. dBA 68 69 71
Dimensions Unit Width mm 900 900 900
    Depth mm 320 320 320
    Height mm 1,345 1,345 1,345
Weight Unit kg 120 120 120
Power supply Phase   1~ 1~ 1~
  Name   V1 V1 V1
  Frequency Hz 50 50 50
  Voltage V 220-440 220-440 220-440
Current Recommended fuses A 25 25 25
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax (2) - Zmax: In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys (system impedance) ≤ Zmax
  (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A (3) - EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated ≤ 75A
  (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A (4) - Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16A
  (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases (5) - Contains fluorinated greenhouse gases