ERQ100A7V1B |
ERQ125A7V1B |
ERQ140A7V1B |
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
|
53
|
55
|
|
Cooling
|
Nom.
|
dBA
|
|
51
|
53
|
Standard Accessories
|
Installation manual
|
1
|
1
|
1
|
|
Operation manual
|
1
|
1
|
1
|
Refrigerant
|
Charge
|
TCO2Eq
|
|
8.4
|
8.4
|
|
GWP
|
|
|
2,087.5
|
2,087.5
|
|
Charge
|
kg
|
|
4.0
|
4.0
|
|
Type
|
|
|
R-410A
|
R-410A
|
Operation range
|
Cooling
|
Max.
|
°CDB
|
|
46
|
46
|
|
|
Min.
|
°CDB
|
|
-5
|
-5
|
|
Heating
|
Max.
|
°CWB
|
|
15.5
|
15.5
|
|
|
Min.
|
°CWB
|
|
-20
|
-20
|
Cooling capacity
|
Nom.
|
kW
|
|
14.0 (1)
|
15.5 (1)
|
Piping connections
|
Liquid
|
OD
|
mm
|
|
9.52
|
9.52
|
|
|
Type
|
|
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
|
15.9
|
19.1
|
|
|
Type
|
|
|
Flare connection
|
Braze connection
|
|
Drain
|
OD
|
mm
|
|
26x3
|
26x3
|
|
|
Quantity
|
|
|
3
|
3
|
Power input
|
Cooling
|
Nom.
|
kW
|
|
3.51 (1)
|
4.53 (1)
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
|
67
|
69
|
COP
|
4.56 (2)
|
4.15 (2)
|
3.94 (2)
|
Dimensions
|
Unit
|
Width
|
mm
|
|
900
|
900
|
|
|
Depth
|
mm
|
|
320
|
320
|
|
|
Height
|
mm
|
|
1,345
|
1,345
|
Weight
|
Unit
|
kg
|
|
120
|
120
|
Fan
|
Air flow rate
|
Heating
|
Nom.
|
m³/min
|
|
105
|
105
|
|
|
Cooling
|
Nom.
|
m³/min
|
|
106
|
106
|
EER
|
3.99 (1)
|
3.99 (1)
|
3.42 (1)
|
Heating capacity
|
Nom.
|
kW
|
|
16.0 (2)
|
18.0 (2)
|
Power supply
|
Phase
|
|
|
1N~
|
1N~
|
|
Name
|
|
|
V1
|
V1
|
|
Frequency
|
Hz
|
|
50
|
50
|
|
Voltage
|
V
|
|
220-240
|
220-240
|
Notes
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
|
|
|
(3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
(3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
|
|
|
(4) - Sound values are measured in a semi-anechoic room.
|
(4) - Sound values are measured in a semi-anechoic room.
|
|
|
(5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
|
(5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
|
|
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
(7) - Maximum allowable voltage range variation between phases is 2%.
|
|
|
(8) - Select wire size based on the value of MCA
|
(8) - Select wire size based on the value of MCA
|
|
|
(9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
|
(9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
|
|
|
(10) - MSC means the maximum current during start up of the compressor
|
(10) - MSC means the maximum current during start up of the compressor
|
|
|
(11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
|
(11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
|
|
|
(12) - Ssc: Short-circuit power
|
(12) - Ssc: Short-circuit power
|
|
|
(13) - Contains fluorinated greenhouse gases
|
(13) - Contains fluorinated greenhouse gases
|
Cooling capacity
|
Nom.
|
kW
|
11.2 (1)
|
Heating capacity
|
Nom.
|
kW
|
12.5 (2)
|
Power input
|
Cooling
|
Nom.
|
kW
|
2.81 (1)
|
|
Heating
|
Nom.
|
kW
|
2.74 (2)
|
Dimensions
|
Unit
|
Height
|
mm
|
1345
|
|
|
Width
|
mm
|
900
|
|
|
Depth
|
mm
|
320
|
Weight
|
Unit
|
kg
|
120
|
Fan
|
Air flow rate
|
Cooling
|
Nom.
|
m³/min
|
106
|
|
|
Heating
|
Nom.
|
m³/min
|
102
|
Operation range
|
Cooling
|
Min.
|
°CDB
|
-5
|
|
|
Max.
|
°CDB
|
46
|
|
Heating
|
Min.
|
°CWB
|
-20
|
|
|
Max.
|
°CWB
|
15.5
|
Sound power level
|
Cooling
|
Nom.
|
dBA
|
66
|
Sound pressure level
|
Cooling
|
Nom.
|
dBA
|
50
|
|
Heating
|
Nom.
|
dBA
|
52
|
Refrigerant
|
Type
|
|
R-410A
|
|
Charge
|
kg
|
4
|
|
Charge
|
tCO2Eq
|
8.4
|
|
GWP
|
|
2087.5
|
Piping connections
|
Liquid
|
Type
|
|
Flare connection
|
|
|
OD
|
mm
|
9.52
|
|
Gas
|
Type
|
|
Flare connection
|
|
|
OD
|
mm
|
15.9
|
|
Drain
|
Quantity
|
|
3
|
|
|
OD
|
mm
|
26x3
|
Power supply
|
Name
|
|
V1
|
|
Phase
|
|
1N~
|
|
Power supply-=-Frequency
|
Frequency
|
|
50
|
|
Power supply-=-Voltage
|
Voltage
|
|
220-240
|
Standard Accessories
|
Connection pipes
|
|
|
3
|