Specifications Table for ERQ-AV1

ERQ100A7V1B ERQ125A7V1B ERQ140A7V1B
Sound pressure level Heating Nom. dBA   53 55
  Cooling Nom. dBA   51 53
Standard Accessories Installation manual 1 1 1
  Operation manual 1 1 1
Refrigerant Charge TCO2Eq   8.4 8.4
  GWP     2,087.5 2,087.5
  Charge kg   4.0 4.0
  Type     R-410A R-410A
Operation range Cooling Max. °CDB   46 46
    Min. °CDB   -5 -5
  Heating Max. °CWB   15.5 15.5
    Min. °CWB   -20 -20
Cooling capacity Nom. kW   14.0 (1) 15.5 (1)
Piping connections Liquid OD mm   9.52 9.52
    Type     Flare connection Flare connection
  Gas OD mm   15.9 19.1
    Type     Flare connection Braze connection
  Drain OD mm   26x3 26x3
    Quantity     3 3
Power input Cooling Nom. kW   3.51 (1) 4.53 (1)
Sound power level Cooling Nom. dBA   67 69
COP 4.56 (2) 4.15 (2) 3.94 (2)
Dimensions Unit Width mm   900 900
    Depth mm   320 320
    Height mm   1,345 1,345
Weight Unit kg   120 120
Fan Air flow rate Heating Nom. m³/min   105 105
    Cooling Nom. m³/min   106 106
EER 3.99 (1) 3.99 (1) 3.42 (1)
Heating capacity Nom. kW   16.0 (2) 18.0 (2)
Power supply Phase     1N~ 1N~
  Name     V1 V1
  Frequency Hz   50 50
  Voltage V   220-240 220-240
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal); level difference: 0m
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m; level difference: 0m
    (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
    (4) - Sound values are measured in a semi-anechoic room. (4) - Sound values are measured in a semi-anechoic room.
    (5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB (5) - RLA is based on following conditions: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB
    (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (6) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
    (7) - Maximum allowable voltage range variation between phases is 2%. (7) - Maximum allowable voltage range variation between phases is 2%.
    (8) - Select wire size based on the value of MCA (8) - Select wire size based on the value of MCA
    (9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). (9) - Use a circuit breaker instead of a fuse. MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker).
    (10) - MSC means the maximum current during start up of the compressor (10) - MSC means the maximum current during start up of the compressor
    (11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase (11) - Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current > 16A and ≤ 75A per phase
    (12) - Ssc: Short-circuit power (12) - Ssc: Short-circuit power
    (13) - Contains fluorinated greenhouse gases (13) - Contains fluorinated greenhouse gases
Cooling capacity Nom. kW 11.2 (1)
Heating capacity Nom. kW 12.5 (2)
Power input Cooling Nom. kW 2.81 (1)
  Heating Nom. kW 2.74 (2)
Dimensions Unit Height mm 1345
    Width mm 900
    Depth mm 320
Weight Unit kg 120
Fan Air flow rate Cooling Nom. m³/min 106
    Heating Nom. m³/min 102
Operation range Cooling Min. °CDB -5
    Max. °CDB 46
  Heating Min. °CWB -20
    Max. °CWB 15.5
Sound power level Cooling Nom. dBA 66
Sound pressure level Cooling Nom. dBA 50
  Heating Nom. dBA 52
Refrigerant Type   R-410A
  Charge kg 4
  Charge tCO2Eq 8.4
  GWP   2087.5
Piping connections Liquid Type   Flare connection
    OD mm 9.52
  Gas Type   Flare connection
    OD mm 15.9
  Drain Quantity   3
    OD mm 26x3
Power supply Name   V1
  Phase   1N~
  Power supply-=-Frequency Frequency   50
  Power supply-=-Voltage Voltage   220-240
Standard Accessories Connection pipes     3