Specifications Table for EPRA08-12EW

EPRA08EAW1 EPRA10EAW1 EPRA12EAW1
Dimensions Unit Height mm 1,003 1,003 1,003
    Width mm 1,270 1,270 1,270
    Depth mm 533 533 533
Weight Unit kg 118 118 118
Fan Air flow rate Heating High m³/min 80.1 80.1 80.1
    Cooling High m³/min 80.1 80.1 80.1
Operation range Cooling Min. °CDB 10 10 10
    Max. °CDB 43 43 43
  Domestic hot water Max. °CDB 35 35 35
    Min. °CDB -28 -28 -28
Piping connections Level difference IU - OU Max. m 10.0 10.0 10.0
Sound power level Heating Nom. dBA 55.6 (1) 55.6 (1) 55.6 (1)
  Cooling Nom. dBA 61.2 (2) 61.4 (2) 60.9 (2)
Sound pressure level Heating Nom. dBA 41.1 (3) 41.1 (3) 41.1 (3)
  Cooling Nom. dBA 47.1 (4) 47.1 (4) 47.2 (4)
Refrigerant Type   R-32 R-32 R-32
  GWP   675.0 675.0 675.0
  Charge kg 3.25 3.25 3.25
Power supply Name   W1 W1 W1
  Phase   3~ 3~ 3~
  Frequency Hz 50 50 50
  Voltage V 400 400 400
Current Recommended fuses A 16 16 16
Notes (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. (3) - Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings.
  (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT = (4) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C ( DT =