Specifications Table for EKHHE-CV3

EKHHE200CV3 EKHHE260CV3
Heat up time Max. hh:mm 08:17:00 10:14:00
COP 4.23 4.23
Domestic hot water Output Nom kW 1.82 1.82
Dimensions Unit Height mm 1607 1892
    Diameter mm 628 628
Weight Unit Empty kg 85 97
Dimensions Unit Height Integrated on indoor unit mm 1607 1892
Weight Packed unit kg 96 109
Installation place Indoor Indoor
Compressor Type   Rotary Rotary
Refrigerant Type   R-134a R-134a
Heat pump Name   EKHHE200CV3 EKHHE260CV3
Refrigerant GWP   1430 1430
  Charge tCO2Eq 0.7 0.7
  Charge kg 1 1
Heat pump Heating capacity kW 0.43 0.43
  Casing Colour   White White
  Dimensions Unit Height mm 1607 1892
      Width mm 628 628
      Depth mm 628 628
  Weight Unit kg 85 97
    Packed unit kg 96 109
  Installation place   Indoor only Indoor only
  Installation IP class   IP24 IP24
    Distance from wall mm 200 200
  Operation range Ambient Min. °CDB -7 -7
      Max. °CDB 43 43
  Sound pressure level Nom. dBA 50 50
    Night quiet mode dBA 50.0 50.0
  Refrigerant Type   R-134A R-134A
    GWP   1430 1430
    Charge tCO2Eq 3.5 3.5
    Charge kg 1 1
  Defrost method   Hot gas defrosting Hot gas defrosting
  System pressure Max. bar 7 7
Tank Integrated heating element power Nom. kW 1.5 1.5
  Casing Colour   White White
    Material   Enamelled steel Enamelled steel
  Installation place   Indoor only Indoor only
  Installation IP class   IP24 IP24
    Solar thermal connection possible   No No
    Tank recirculation opening   No No
General Product description Air-to-water heat pump   Yes Yes
    Model identifier   EKHHE200CV3 EKHHE260CV3
  Supplementary heater Type of energy input   Electricity Electricity
  Supplier/Manufacturer details Name or trademark   Daikin Europe N.V. Daikin Europe N.V.
  LW(A) Sound power level (according to EN14825) Indoor dBA 50 50
Domestic hot water heating General Declared load profile   L XL
    Function to fix water heating during off peak hours   Yes Yes
    Water heating energy efficiency class   A+ A+
    Thermostat temperature setting °C 55 55
Sound power level Domestic hot water heating Outdoor unit dBA 49 49
    Indoor unit dBA 50 50
Domestic hot water heating Average climate AEC (Annual electricity consumption) kWh 758 1203
    Qelec (Daily electricity consumption) kWh 2.08 3.30
  Cold climate AEC (Annual electricity consumption) kWh 979 1672
    Qelec (Daily electricity consumption) kWh 2.68 4.58
  Warm climate AEC (Annual electricity consumption) kWh 698 1132
    Qelec (Daily electricity consumption) kWh 1.91 3.10
Energy Efficiency Range A+ ~ F A+ ~ F
Heat pump Power supply Phase   1P 1P
    Frequency Hz 50 50
    Voltage V 230 230
    Maximum running current A 8.5 8.5
    Recommended field use A 2.43 2.43
Tank Power supply Phase   1P 1P
    Frequency Hz 50 50
    Voltage V 230 230