| EKHH2E260PAAV3 | |||||
|---|---|---|---|---|---|
| Heat up time | Max. | hh:mm | 10:14:00, 07:56:46 | ||
| COP | 3.10, 3.60 | ||||
| Domestic hot water | Output | Nom | kW | 1.8 | |
| Equivalent hot water | Max | l | 342 | ||
| Dimensions | Unit | Height | mm | 2000 | |
| Diameter | mm | 650 | |||
| Weight | Unit | Empty | kg | 112 | |
| Full | kg | 358 | |||
| Packed unit | kg | 132 | |||
| Installation place | Indoor | ||||
| IP class | IP-X4 | ||||
| Compressor | Type | Rotary non-inverter | |||
| Refrigerant | Type | R-134a | |||
| GWP | 1430.0 | ||||
| Charge | tCO2Eq | 1.29 | |||
| Charge | kg | 0.900 | |||
| Heat pump | Casing | Colour | White body / black top | ||
| Material | Cover: EPP top finishing | ||||
| Operation range | Ambient | Min. | °CDB | -7 | |
| Max. | °CDB | 38 | |||
| Defrost method | Active with hot gas valve | ||||
| Automatic defrost start | °C | -2 | |||
| System pressure | Max. | bar | 7 | ||
| Tank | Operation range | Water side | Max. | °C | 56 |
| Min. | °C | 10 | |||
| Integrated heating element power | Nom. | kW | 1.5 | ||
| Casing | Colour | White | |||
| Material | Embossed ABS | ||||
| Dimensions | Unit | Height | mm | 1500 | |
| Installation | Solar thermal connection possible | Yes | |||
| General | Product description | Air-to-water heat pump | Yes | ||
| Supplier/Manufacturer details | Name and address | ELIC - Via Pietro Zorutti 13/14, 33074 Fontanafredda ITALY | |||
| Domestic hot water heating | General | Declared load profile | XL | ||
| Water heating energy efficiency class | A+ | ||||
| Thermostat temperature setting | °C | 55 | |||
| Sound power level | Domestic hot water heating | Outdoor unit | dBA | 52 | |
| Indoor unit | dBA | 53 | |||
| Domestic hot water heating | Average climate | AEC (Annual electricity consumption) | kWh | 1323 | |
| Cold climate | AEC (Annual electricity consumption) | kWh | 1826 | ||
| Warm climate | AEC (Annual electricity consumption) | kWh | 1296 | ||
| Energy Efficiency Range | A+ ~ F | ||||
| Heat pump | Power supply | Phase | 1P | ||
| Frequency | Hz | 50 | |||
| Voltage | V | 230 | |||
| Maximum running current | A | 2 | |||
| Tank | Power supply | Phase | 1P | ||
| Frequency | Hz | 50 | |||
| Voltage | V | 230 | |||
| Notes | (1) - According to EN16147-2011, inlet temperature 7°C, room temperature 20°C, cold water inlet 10°C | ||||
| (2) - According to EN16147-2011, inlet temperature 15°C, room temperature 20°C, cold water inlet 10°C | |||||