EKHH2E200BAV33 |
Sound power level
|
Domestic hot water heating
|
Indoor unit
|
dBA
|
53
|
|
|
Outdoor unit
|
dBA
|
52
|
Equivalent hot water
|
Max
|
l
|
266
|
Heat pump
|
Automatic defrost start
|
°C
|
-2
|
|
Operation range
|
Ambient
|
Min.
|
°CDB
|
-7
|
|
|
|
Max.
|
°CDB
|
38
|
|
Casing
|
Material
|
|
Cover: EPP top finishing
|
|
|
Colour
|
|
White body / grey top
|
|
System pressure
|
Max.
|
bar
|
7
|
|
Defrost method
|
|
Active with hot gas valve
|
Domestic hot water heating
|
General
|
Water heating energy efficiency class
|
|
A+
|
|
|
Thermostat temperature setting
|
°C
|
55
|
|
|
Declared load profile
|
|
L
|
|
Average climate
|
AEC (Annual electricity consumption)
|
kWh
|
752
|
COP
|
3.28 (1)
|
Refrigerant
|
GWP
|
|
1,430.0
|
|
Charge
|
kg
|
1.3
|
|
Type
|
|
R-134a
|
Dimensions
|
Unit
|
Diameter
|
mm
|
650
|
|
|
Height
|
mm
|
1,744
|
Compressor
|
Type
|
|
Rotary non-inverter
|
Domestic hot water
|
Output
|
Nom
|
kW
|
1.89
|
Tank
|
Installation
|
Solar thermal connection possible
|
|
No
|
|
Integrated heating element power
|
Nom.
|
kW
|
1.5
|
|
Casing
|
Material
|
|
Embossed ABS
|
|
|
Colour
|
|
White
|
|
Dimensions
|
Unit
|
Height
|
mm
|
1,240
|
|
Operation range
|
Water side
|
Max.
|
°C
|
56
|
|
|
|
Min.
|
°C
|
10
|
Weight
|
Packed unit
|
kg
|
105
|
|
Unit
|
Empty
|
kg
|
85
|
|
|
Full
|
kg
|
281
|
Installation place
|
Indoor
|
IP class
|
IP-X4
|
General
|
Product description
|
Air-to-water heat pump
|
|
Yes
|
|
Supplier/Manufacturer details
|
Name and address
|
|
E.L.I.C. - Via Pietro Zorutti 13/14/16, 33074 Fontanafredda ITALY
|
Heat up time
|
Max.
|
hh:mm
|
07:05:00, See note 1, See note 2
|
Heat pump
|
Power supply
|
Frequency
|
Hz
|
50
|
|
|
Maximum running current
|
A
|
2.4
|
|
|
Phase
|
|
1P
|
|
|
Voltage
|
V
|
230
|
Tank
|
Power supply
|
Phase
|
|
1P
|
|
|
Frequency
|
Hz
|
50
|
|
|
Voltage
|
V
|
230
|
Notes
|
(1) - Test at Ta DB/WB 7°C/6°C. According to EN 16147.
|
|
(2) - Test at Ta DB/WB 14°C/13°C. According to EN 16147.
|
|