Specifications Table for EKHH2E-AV3

EKHH2E200AAV3 EKHH2E260AAV3
Sound power level Domestic hot water heating Indoor unit dBA 53 53
    Outdoor unit dBA 52 52
Equivalent hot water Max l 275 342
Heat pump Automatic defrost start °C -2 -2
  Operation range Ambient Min. °CDB -7 -7
      Max. °CDB 38 38
  Casing Material   Cover: EPP top finishing Cover: EPP top finishing
    Colour   White body / black top White body / black top
  System pressure Max. bar 7 7
  Defrost method   Active with hot gas valve Active with hot gas valve
Domestic hot water heating General Water heating energy efficiency class   A+ A+
    Thermostat temperature setting °C 55 55
    Declared load profile   L XL
  Cold climate AEC (Annual electricity consumption) kWh 1,091 1,826
  Warm climate AEC (Annual electricity consumption) kWh 756 1,296
  Average climate AEC (Annual electricity consumption) kWh 835 1,323
COP 2.94 (1), 3.30 (2) 3.10 (1), 3.60 (2)
Refrigerant GWP   1,430.0 1,430.0
  Charge kg 0.900 0.900
  Type   R-134a R-134a
Dimensions Unit Diameter mm 650 650
    Height mm 1,714 2,000
Compressor Type   Rotary non-inverter Rotary non-inverter
Domestic hot water Output Nom kW 1.8 1.8
Tank Installation Solar thermal connection possible   No No
  Integrated heating element power Nom. kW 1.5 1.5
  Casing Material   Embossed ABS Embossed ABS
    Colour   White White
  Dimensions Unit Height mm 1,210 1,500
  Operation range Water side Max. °C 56 56
      Min. °C 10 10
Weight Packed unit kg 103 115
  Unit Empty kg 83 95
    Full kg 282 349
Installation place Indoor Indoor
IP class IP-X4 IP-X4
General Product description Air-to-water heat pump   Yes Yes
  Supplier/Manufacturer details Name and address   ELIC - Via Pietro Zorutti 13/14, 33074 Fontanafredda ITALY ELIC - Via Pietro Zorutti 13/14, 33074 Fontanafredda ITALY
Heat up time Max. hh:mm 08:17:00, 06:30:44 10:14:00, 07:56:46
Heat pump Power supply Frequency Hz 50 50
    Maximum running current A 2 2
    Phase   1P 1P
    Voltage V 230 230
Tank Power supply Phase   1P 1P
    Frequency Hz 50 50
    Voltage V 230 230
Notes (1) - According to EN16147-2011, inlet temperature 7°C, room temperature 20°C, cold water inlet 10°C (1) - According to EN16147-2011, inlet temperature 7°C, room temperature 20°C, cold water inlet 10°C
  (2) - According to EN16147-2011, inlet temperature 15°C, room temperature 20°C, cold water inlet 10°C (2) - According to EN16147-2011, inlet temperature 15°C, room temperature 20°C, cold water inlet 10°C
  (3) - Indoor temperature : 29°CDB, 19°CWB; outdoor temperature : 46°CDB, 24°CWB (3) - Indoor temperature : 29°CDB, 19°CWB; outdoor temperature : 46°CDB, 24°CWB
  (4) - Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB (4) - Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB