Specifications Table for EHYHBX-AV3 / EVLQ-CV3

EHYHBX08AAV3 / EVLQ08CAV3 EHYHBX08AFV3 / EVLQ08CAV3
Domestic hot water heating General Declared load profile   XL XL
  Average climate Water heating energy efficiency class   A A
COP 4.45 (3), 3.42 (4) 4.45 (3), 3.42 (4)
Space heating Average climate water outlet 35°C General ηs (Seasonal space heating efficiency) % 168 168
      Seasonal space heating eff. class   A++ A++
      SCOP   4.28 4.28
  Average climate water outlet 55°C General Seasonal space heating eff. class   A++ A++
      ηs (Seasonal space heating efficiency) % 129 129
      SCOP   3.29 3.29
Cooling capacity Nom. kW 6.86 (4), 5.36 (4) 6.86 (4), 5.36 (4)
  Min. kW 2.50 (3), 2.50 (4) 2.50 (3), 2.50 (4)
EER 3.42 (3), 2.29 (4) 3.42 (3), 2.29 (4)
Heating capacity Nom. kW 7.40 (3), 6.89 (4) 7.40 (3), 6.89 (4)
  Min. kW 1.80 (3), 1.80 (4) 1.80 (3), 1.80 (4)
  Max. kW 10.0 (3), 9.53 (4) 10.0 (3), 9.53 (4)
Power input Heating Nom. kW 1.66 (3), 2.01 (4) 1.66 (3), 2.01 (4)
  Cooling Nom. kW 2.01 (3), 2.34 (4) 2.01 (3), 2.34 (4)
Notes (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) (2) - Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C)
  (3) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (3) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (4) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (4) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (5) - Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed (5) - Tamb 35°C - LWE 7°C (DT=5°C), boiler bypassed
  (6) - Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed (6) - Tamb 35°C - LWE 18°C (DT=5°C), boiler bypassed
  (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed
  (8) - DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed (8) - DB/WB 7°C/6°C - LWC 45°C (DT=5°C), boiler bypassed