Specifications Table for EHVZ-CB3V

EHVZ04S18CB3V EHVZ08S18CB3V EHVZ16S18CB3V
Sound pressure level Nom. dBA 28 (7) 28 (7) 30 (7)
Sound power level Nom. dBA 42 (6) 42 (6) 44 (6)
Dimensions Unit Width mm 600 600 600
    Depth mm 728 728 728
    Height mm 1,732 1,732 1,732
Casing Material   Precoated sheet metal Precoated sheet metal Precoated sheet metal
  Colour   White White White
Weight Unit kg 121 122 121
PED Category   Art3§3, See note 1 Category I, See note 1 Art3§3, See note 1
Wiring connections For connection with user interface Remark   0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m) 0.75 mm² till 1.25 mm² (max length 500m)
    Quantity   2 2 2
Power supply Name   See note 12 See note 12 See note 12
Electric heater Power supply Frequency Hz 50 50 50
    Voltage V 230 230 230
    Name   3V3 3V3 3V3
    Phase   1~ 1~ 1~
Notes (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (1) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (2) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (3) - Heatloss according to EN12897 (3) - Heatloss according to EN12897 (3) - Heatloss according to EN12897
  (4) - Drain/Fill valve only available on water inlet connection. (4) - Drain/Fill valve only available on water inlet connection. (4) - Drain/Fill valve only available on water inlet connection.
  (5) - Including piping + PHE + back-up heater; excluding expansion vessel (5) - Including piping + PHE + back-up heater; excluding expansion vessel (5) - Including piping + PHE + back-up heater; excluding expansion vessel
  (6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) (6) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C)
  (7) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (7) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. (7) - The sound pressure level is measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
  (8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning (8) - 15°C-25°C: BUH only, no heat pump operation = during commissioning
  (9) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (9) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models (9) - Refer to operation range for detail for differences between *RHQ* and *RLQ* models
  (10) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation (10) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation (10) - For *RLQ* outdoor units >55°C BUH only, no heatpump operation
  (11) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation (11) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation (11) - For *RHQ* outdoor units >50°C BUH only, no heatpump operation
  (12) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. (12) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. (12) - Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit.
  (13) - Select diameter and type according to national and local regulations (13) - Select diameter and type according to national and local regulations (13) - Select diameter and type according to national and local regulations