| EGSQH10S18AA9W | |||||
|---|---|---|---|---|---|
| Sound pressure level | Nom. | dBA | 32.0 (6) | ||
| Refrigerant | GWP | 2,090 | |||
| Charge | kg | 1.80 | |||
| Type | R-410A | ||||
| Operation range | Installation space | Min. | °C | 5.00 | |
| Max. | °C | 30.0 | |||
| Heating | Water side | Max. | °C | 60.0 (7), 65.0 (8) | |
| Min. | °C | 24 (7), 24 (8) | |||
| Brine side | Min. | °C | -5.00 | ||
| Max. | °C | 20.0 | |||
| Domestic hot water | Water side | Max. | °C | 55 (7), 60 (9) | |
| Min. | °C | 25 (7), 25 (9) | |||
| Power input | Nom. | kW | 2.38 (1), 2.89 (2) | ||
| Sound power level | Nom. | dBA | 46.0 | ||
| COP | 4.33 (1), 3.18 (2) | ||||
| Dimensions | Unit | Width | mm | 600 | |
| Depth | mm | 728 | |||
| Height | mm | 1,730 | |||
| Casing | Material | Precoated sheet metal | |||
| Colour | White | ||||
| Tank | Water volume | l | 180 | ||
| Corrosion protection | Anode | ||||
| Insulation | Heat loss | kWh/24h | 1.36 (4) | ||
| Weight | Unit | kg | 210 | ||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 194 | 
| Seasonal space heating eff. class | A+++ | ||||
| SCOP | 5.06 | ||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A++ | ||
| ηs (Seasonal space heating efficiency) | % | 139 | |||
| SCOP | 3.68 | ||||
| Heating capacity | Nom. | kW | 10.3 (1), 9.20 (2) | ||
| Min. | kW | 3.11 (1), 2.47 (2) | |||
| Max. | kW | 13.0 (1), 11.9 (2) | |||
| Power supply | Phase | 3~ | |||
| Name | 9W | ||||
| Frequency | Hz | 50 | |||
| Voltage | V | 400 | |||
| Current | Recommended fuses | A | 25 | ||
| Notes | (1) - EWB/LWB 0°C/-3°C - LWC 35°C (DT=5°C) | ||||
| (2) - EWB/LWB 0°C/-3°C - LWC 45°C (DT=5°C) | |||||
| (3) - with 40% propylene glycol | |||||
| (4) - Heatloss according to EN12897 | |||||
| (5) - Including piping + PHE + back-up heater; excluding expansion vessel | |||||
| (6) - The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. | |||||
| (7) - By heat pump | |||||
| (8) - By heat pump + back-up heater | |||||
| (9) - By back-up heater | |||||