| EGSAX06DA9WG | EGSAX10DA9WG | |||||
|---|---|---|---|---|---|---|
| Heating capacity | Min. | kW | 0.85 | |||
| Nom. | kW | 3.35 | ||||
| Max. | kW | 7.98 | ||||
| Power input | Nom. | kW | 0.74 | |||
| COP | 4.51 | |||||
| Casing | Colour | Grey + Black | ||||
| Dimensions | Unit | Height | mm | 1,891 | ||
| Width | mm | 597 | ||||
| Depth | mm | 666 | ||||
| Weight | Unit | kg | 222 | |||
| Tank | Water volume | l | 180 | |||
| Insulation | Heat loss | kWh/24h | 1.2 | |||
| Corrosion protection | Pickling | |||||
| Refrigerant | Type | R-32 | ||||
| GWP | 675.0 | |||||
| Charge | kg | 1.70 | ||||
| Operation range | Installation space | Min. | °C | 5 | ||
| Max. | °C | 35 | ||||
| Brine side | Min. | °C | -10 | |||
| Max. | °C | 30 | ||||
| Heating | Water side | Min. | °C | 5 | ||
| Max. | °C | 65 | ||||
| Domestic hot water | Water side | Min. | °C | 25 | ||
| Max. | °C | 60 | ||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.77 (1) | ||
| Seasonal space heating eff. class | A++ | |||||
| Average climate water outlet 35°C | General | SCOP | 5.18 (1) | |||
| Seasonal space heating eff. class | A+++ | |||||
| Power supply | Phase | 1~/3~ | ||||
| Frequency | Hz | 50 | ||||
| Voltage | V | 230/400 | ||||
| Current | Recommended fuses | A | 16/32 | |||
| Notes | (1) - According to EN14825 and EN14511:2018 | |||||
| (2) - See operation range drawing: range increase by support booster heater or backup heater | ||||||
| Heating capacity | Min. | kW | 0.85 | |||
| Nom. | kW | 5.49 | ||||
| Max. | kW | 9.55 | ||||
| Power input | Nom. | kW | 1.17 | |||
| COP | 4.7 | |||||
| Casing | Colour | Grey + Black | ||||
| Dimensions | Unit | Height | mm | 1891 | ||
| Width | mm | 597 | ||||
| Depth | mm | 666 | ||||
| Weight | Unit | kg | 222 | |||
| Tank | Insulation | Heat loss | kWh/24h | 1.2 | ||
| Corrosion protection | Pickling | |||||
| Refrigerant | Type | R-32 | ||||
| GWP | 675.0 | |||||
| Charge | tCO2Eq | 1.15 | ||||
| Charge | kg | 1.70 | ||||
| Space heating | Average climate water outlet 55°C | General | SCOP | 4.05 (1) | ||
| Seasonal space heating eff. class | A+++ | |||||
| Average climate water outlet 35°C | General | SCOP | 5.20 (1) | |||
| Seasonal space heating eff. class | A+++ | |||||
| Power supply | Phase | 1~/3~ | ||||
| Frequency | Hz | 50 | ||||
| Voltage | V | 230/400 | ||||
| Current | Recommended fuses | A | 16/32 | |||
| Notes | (1) - According to EN14825 and EN14511:2018 | |||||