Specifications Table for EBLQ-CV3

EBLQ05CAV3 EBLQ07CAV3
Sound pressure level Heating Nom. dBA 48 (8) 49 (8)
  Cooling Nom. dBA 48 (8) 50 (8)
Refrigerant GWP   2,088 2,088
  Charge kg 1.30 1.45
  Type   R-410A R-410A
Operation range Cooling Ambient Max. °CDB 43.0 43.0
      Min. °CDB 10.0 10.0
    Water side Max. °C 22.0 22.0
      Min. °C 5.00 (5) 5.00 (5)
  Heating Water side Max. °C 55.0 55.0
      Min. °C 15 (4) 15 (4)
  Domestic hot water Water side Max. °C 80 (7) 80 (7)
      Min. °C 25 25
    Ambient Min. °CDB -25.0 (6) -25.0 (6)
      Max. °CDB 35.0 (6) 35.0 (6)
Cooling capacity Nom. kW 3.88 (1), 3.99 (2) 5.20 (1), 5.15 (2)
Power input Cooling Nom. kW 0.950 (1), 1.93 (2) 1.37 (1), 2.69 (2)
  Heating Nom. kW 0.880 (1), 1.13 (2) 1.55 (1), 2.45 (2)
Sound power level Heating Nom. dBA 61 62
  Cooling Nom. dBA 63.0 63.0
COP 5.00 (1), 3.58 (2) 4.52 (1), 3.42 (2)
Dimensions Unit Width mm 1,090 1,090
    Depth mm 350 350
    Height mm 735 735
Weight Unit kg 76.0 80.0
Space heating Average climate water outlet 35°C General ηs (Seasonal space heating efficiency) % 175 164
      Seasonal space heating eff. class   A++ A++
      SCOP   4.45 4.18
  Average climate water outlet 55°C General Seasonal space heating eff. class   A++ A++
      ηs (Seasonal space heating efficiency) % 126 126
      SCOP   3.22 3.22
Fan Air flow rate Heating High m³/min 45.0 47.0
    Cooling High m³/min 52.5 52.5
EER 4.07 (1), 2.07 (2) 3.80 (1), 2.10 (2)
Heating capacity Nom. kW 4.40 (1), 4.03 (2) 7.00 (1), 6.90 (2)
Power supply Phase   1~ 1~
  Name   V3 V3
  Frequency Hz 50 50
  Voltage V 230 230
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
  (4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C
  (5) - For more details on standard accessories refer to Installation/operation manual (5) - For more details on standard accessories refer to Installation/operation manual
  (6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. (6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
  (7) - > 50°C BSH only, no heatpump operation (7) - > 50°C BSH only, no heatpump operation
  (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (10) - Including piping + PHE; excluding expansion vessel (10) - Including piping + PHE; excluding expansion vessel
  (11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current (11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current