EBLQ05CAV3 |
EBLQ07CAV3 |
Sound pressure level
|
Heating
|
Nom.
|
dBA
|
48 (8)
|
49 (8)
|
|
Cooling
|
Nom.
|
dBA
|
48 (8)
|
50 (8)
|
Refrigerant
|
GWP
|
|
2,088
|
2,088
|
|
Charge
|
kg
|
1.30
|
1.45
|
|
Type
|
|
R-410A
|
R-410A
|
Operation range
|
Cooling
|
Ambient
|
Max.
|
°CDB
|
43.0
|
43.0
|
|
|
|
Min.
|
°CDB
|
10.0
|
10.0
|
|
|
Water side
|
Max.
|
°C
|
22.0
|
22.0
|
|
|
|
Min.
|
°C
|
5.00 (5)
|
5.00 (5)
|
|
Heating
|
Water side
|
Max.
|
°C
|
55.0
|
55.0
|
|
|
|
Min.
|
°C
|
15 (4)
|
15 (4)
|
|
Domestic hot water
|
Water side
|
Max.
|
°C
|
80 (7)
|
80 (7)
|
|
|
|
Min.
|
°C
|
25
|
25
|
|
|
Ambient
|
Min.
|
°CDB
|
-25.0 (6)
|
-25.0 (6)
|
|
|
|
Max.
|
°CDB
|
35.0 (6)
|
35.0 (6)
|
Cooling capacity
|
Nom.
|
kW
|
3.88 (1), 3.99 (2)
|
5.20 (1), 5.15 (2)
|
Power input
|
Cooling
|
Nom.
|
kW
|
0.950 (1), 1.93 (2)
|
1.37 (1), 2.69 (2)
|
|
Heating
|
Nom.
|
kW
|
0.880 (1), 1.13 (2)
|
1.55 (1), 2.45 (2)
|
Sound power level
|
Heating
|
Nom.
|
dBA
|
61
|
62
|
|
Cooling
|
Nom.
|
dBA
|
63.0
|
63.0
|
COP
|
5.00 (1), 3.58 (2)
|
4.52 (1), 3.42 (2)
|
Dimensions
|
Unit
|
Width
|
mm
|
1,090
|
1,090
|
|
|
Depth
|
mm
|
350
|
350
|
|
|
Height
|
mm
|
735
|
735
|
Weight
|
Unit
|
kg
|
76.0
|
80.0
|
Space heating
|
Average climate water outlet 35°C
|
General
|
ηs (Seasonal space heating efficiency)
|
%
|
175
|
164
|
|
|
|
Seasonal space heating eff. class
|
|
A++
|
A++
|
|
|
|
SCOP
|
|
4.45
|
4.18
|
|
Average climate water outlet 55°C
|
General
|
Seasonal space heating eff. class
|
|
A++
|
A++
|
|
|
|
ηs (Seasonal space heating efficiency)
|
%
|
126
|
126
|
|
|
|
SCOP
|
|
3.22
|
3.22
|
Fan
|
Air flow rate
|
Heating
|
High
|
m³/min
|
45.0
|
47.0
|
|
|
Cooling
|
High
|
m³/min
|
52.5
|
52.5
|
EER
|
4.07 (1), 2.07 (2)
|
3.80 (1), 2.10 (2)
|
Heating capacity
|
Nom.
|
kW
|
4.40 (1), 4.03 (2)
|
7.00 (1), 6.90 (2)
|
Power supply
|
Phase
|
|
1~
|
1~
|
|
Name
|
|
V3
|
V3
|
|
Frequency
|
Hz
|
50
|
50
|
|
Voltage
|
V
|
230
|
230
|
Notes
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
(1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
|
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
(2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
|
|
(3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
(3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
|
|
(4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C
|
(4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C
|
|
(5) - For more details on standard accessories refer to Installation/operation manual
|
(5) - For more details on standard accessories refer to Installation/operation manual
|
|
(6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
|
(6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
|
|
(7) - > 50°C BSH only, no heatpump operation
|
(7) - > 50°C BSH only, no heatpump operation
|
|
(8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
|
(8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
|
|
(9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
|
(9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
|
|
(10) - Including piping + PHE; excluding expansion vessel
|
(10) - Including piping + PHE; excluding expansion vessel
|
|
(11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current
|
(11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current
|