| DucoBox Energy Sky D275 UK | |||||
|---|---|---|---|---|---|
| Article number | 00004940 | ||||
| Casing | Material | Expanded Polypropylene + Polystyrene | |||
| Dimensions | Unit | Height | mm | 1180 | |
| Width | mm | 670 | |||
| Depth | mm | 295 | |||
| Weight | Unit | kg | 19 | ||
| Fan | Air flow rate - 50Hz | Heat exchange mode | Ultra high | m³/h | 275 |
| Bypass mode | Ultra high | m³/h | 275 | ||
| Heat exchange system | Air to air cross flow heat exchange | ||||
| Heat exchange element | v1: PP - v2: PET/Alu | ||||
| Connection duct diameter | mm | Internal diameter Ø160 | |||
| Operation mode | Heat exchange mode, Bypass mode, Frost protection mode | ||||
| SEC class | A+ (1) | ||||
| Maximum flow rate at 100 Pa ESP | Flow rate | m³/h | 275 | ||
| Sound power level (Lwa) | dB | 45 | |||
| Annual electricity consumption | kWh/a | 115.8 | |||
| Annual heating saved | Average climate | kWh/a | 4620 (2) | ||
| Cold climate | kWh/a | 9038 (2) | |||
| Warm climate | kWh/a | 2089 (2) | |||
| Power supply | Phase | 3-core power cable with earthed plug | |||
| Frequency | Hz | 50 | |||
| Voltage | V | 230 | |||
| Notes | (1) - With 2 sensors (control factor 0.65): A+ ; Other: A | ||||
| (2) - Manual control (no DCV) | |||||