CTXM15R2V1B / CTXM15R2V1B / 2MXM40N2V1B |
CTXM15R2V1B / CTXM15R2V1B / 2MXM50N2V1B |
CTXM15R5V1B / CTXM15R5V1B / 2MXM40N2V1B |
CTXM15R5V1B / CTXM15R5V1B / 2MXM50N2V1B |
Cooling capacity
|
Nom.
|
kW
|
3.00
|
3.00
|
3.00
|
3.00
|
Space cooling
|
SEER
|
|
8.66
|
8.80
|
8.66
|
8.80
|
|
Annual energy consumption
|
kWh/a
|
122
|
120
|
122
|
120
|
|
Capacity
|
Pdesign
|
kW
|
3.00
|
3.00
|
3.00
|
3.00
|
|
Energy efficiency class
|
|
A+++
|
A+++
|
A+++
|
A+++
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
3.00
|
3.30
|
3.00
|
3.30
|
|
SCOP/A
|
|
4.62
|
4.79
|
4.62
|
4.79
|
|
Energy efficiency class
|
|
A++
|
A++
|
A++
|
A++
|
|
Pdh Heating capacity at -10°
|
kW
|
2.41
|
2.82
|
2.41
|
2.82
|
|
Annual energy consumption
|
kWh/a
|
908
|
965
|
908
|
965
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
302
|
310
|
302
|
310
|
|
EER
|
|
4.97
|
4.84
|
4.97
|
4.84
|
|
COP
|
|
4.35
|
4.58
|
4.35
|
4.58
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
A
|
|
|
Heating
|
|
A
|
A
|
A
|
A
|
Heating capacity
|
Nom.
|
kW
|
3.50
|
4.00
|
3.50
|
4.00
|
Notes
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|