Specifications Table for CTXM-R / 2MXM-N

CTXM15R2V1B / CTXM15R2V1B / 2MXM40N2V1B CTXM15R2V1B / CTXM15R2V1B / 2MXM50N2V1B CTXM15R5V1B / CTXM15R5V1B / 2MXM40N2V1B CTXM15R5V1B / CTXM15R5V1B / 2MXM50N2V1B
Cooling capacity Nom. kW 3.00 3.00 3.00 3.00
Space cooling SEER   8.66 8.80 8.66 8.80
  Annual energy consumption kWh/a 122 120 122 120
  Capacity Pdesign kW 3.00 3.00 3.00 3.00
  Energy efficiency class   A+++ A+++ A+++ A+++
Space heating (Average climate) Capacity Pdesign kW 3.00 3.30 3.00 3.30
  SCOP/A   4.62 4.79 4.62 4.79
  Energy efficiency class   A++ A++ A++ A++
  Pdh Heating capacity at -10° kW 2.41 2.82 2.41 2.82
  Annual energy consumption kWh/a 908 965 908 965
Nominal efficiency Annual energy consumption kWh 302 310 302 310
  EER   4.97 4.84 4.97 4.84
  COP   4.35 4.58 4.35 4.58
  Energy labeling Directive Cooling   A A A A
    Heating   A A A A
Heating capacity Nom. kW 3.50 4.00 3.50 4.00
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data