| ATXM25R2V1B / ARXM25N5V1B9 | ATXM25R5V1B / ARXM25N5V1B9 | ATXM35R2V1B / ARXM35N5V1B9 | ATXM35R5V1B / ARXM35N5V1B9 | ATXM50R2V1B / ARXM50N2V1B9 | ||||
|---|---|---|---|---|---|---|---|---|
| Cooling capacity | Min. | kW | 1.30 | 1.30 | 1.40 | 1.40 | 1.70 | |
| Max. | kW | 3.20 | 3.20 | 4.00 | 4.00 | 6.00 | ||
| Nom. | kW | 2.50 | 2.50 | 3.40 | 3.40 | 5.00 | ||
| Space cooling | SEER | 8.55 | 8.55 | 8.55 | 8.55 | 7.35 | ||
| Annual energy consumption | kWh/a | 102 | 102 | 139 | 139 | 238 | ||
| Capacity | Pdesign | kW | 2.50 | 2.50 | 3.40 | 3.40 | 5.00 | |
| Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A++ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 2.40 | 2.40 | 2.50 | 2.50 | 4.60 |
| SCOP/A | 5.10 | 5.10 | 5.10 | 5.10 | 4.65 | |||
| Energy efficiency class | A+++ | A+++ | A+++ | A+++ | A++ | |||
| Annual energy consumption | kWh/a | 659 | 659 | 687 | 687 | 1,384 | ||
| Nominal efficiency | Annual energy consumption | kWh | 285 | 285 | 416 | 416 | 725 | |
| EER | 4.39 | 4.39 | 4.09 | 4.09 | 3.45 | |||
| COP | 5.00 | 5.00 | 4.04 | 4.04 | 3.79 | |||
| Energy labeling Directive | Cooling | A | A | A | A | A | ||
| Heating | A | A | A | A | A | |||
| Heating capacity | Nom. | kW | 2.80 | 2.80 | 4.00 | 4.00 | 5.80 | |
| Min. | kW | 1.30 | 1.30 | 1.40 | 1.40 | 1.70 | ||
| Max. | kW | 4.70 | 4.70 | 5.20 | 5.20 | 7.70 | ||
| Notes | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | (1) - See separate drawing for operation range | |||
| (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | (2) - See separate drawing for electrical data | ||||
| (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||