FTXTP35K3V1B / RXTP35N2V1B FTXTP25K3V1B / RXTP25N2V1B
Indoor unit FTXTP35K3V1B FTXTP25K3V1B
Outdoor unit RXTP35N2V1B RXTP25N2V1B
Cooling capacity Min. kW 0.70 0.70
  Min. Btu/h 2,380 2,380
  Min. kcal/h 601 601
  Nom. kW 3.50 2.50
  Nom. Btu/h 11,940 8,530
  Nom. kcal/h 3,009 2,149
  Max. kW 4.40 4.00
  Max. Btu/h 15,010 13,640
  Max. kcal/h 3,783 3,439
Heating capacity Min. kW 0.80 0.80
  Min. Btu/h 2,720 2,720
  Min. kcal/h 687 687
  Nom. kW 4.00 3.20
  Nom. Btu/h 13,640 10,910
  Nom. kcal/h 3,439 2,751
  Max. kW 6.70 6.20
  Max. Btu/h 22,860 21,150
  Max. kcal/h 5,760 5,331
Power input Cooling Nom. kW 0.91 0.57
  Heating Nom. kW 0.88 0.68
Nominal efficiency EER   3.80 4.40
  COP   4.44 4.95
  Annual energy consumption kWh 460 (0.000) 285 (0.000)
  Energy labeling Directive Cooling   A A
    Heating   A A
Space cooling Capacity Pdesign kW 3.50 2.50
  Energy efficiency class   A++ A++
  SEER   7.20 7.10
  Annual energy consumption kWh/a 170 123
  A Condition (35°C - 27/19) Pdc kW 3.50 2.50
    EERd   3.80 4.40
    Power input kW 0.92 0.57
  B Condition (30°C - 27/19) Pdc kW 2.58 1.84
    EERd   5.67 6.54
    Power input kW 0.46 0.29
  C Condition (25°C - 27/19) Pdc kW 1.66 1.18
    EERd   9.50 8.73
    Power input kW 0.18 0.14
  D Condition (20°C - 27/19) Pdc kW 0.93 0.84
    EERd   9.13 8.54
    Power input kW 0.11 0.10
Space heating (Average climate) Capacity Pdesign kW 3.00 2.50
  Energy efficiency class   A++ A++
  SCOP/A   4.81 4.98
  SCOPnet/A   4.82 4.99
  Pdh Heating capacity at -10° kW 3.00 2.50
  Annual energy consumption kWh/a 873 703
  Required back up heating cap at design conditions kW 0.00 0.00
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 3.30 2.90
    COPd (declared COP)   1.56 1.56
    Power input kW 2.12 1.86
  TBivalent Tbiv (bivalent temperature) °C -10 -10
    Pdh (declared heating cap) kW 3.00 2.50
    COPd (declared COP)   2.77 3.09
    Power input kW 1.08 0.81
  A Condition (-7°C) Pdh (declared heating cap) kW 2.65 2.21
    COPd (declared COP)   3.13 3.39
    Power input kW 0.85 0.65
  B Condition (2°C) Pdh (declared heating cap) kW 1.62 1.35
    COPd (declared COP)   4.89 5.05
    Power input kW 0.33 0.27
  C Condition (7°C) Pdh (declared heating cap) kW 1.04 0.87
    COPd (declared COP)   5.81 5.94
    Power input kW 0.18 0.15
  D Condition (12°C) Pdh (declared heating cap) kW 1.08 1.08
    COPd (declared COP)   7.60 7.60
    Power input kW 0.14 0.14
Space heating (Cold climate) Capacity Pdesignh kW 4.40 3.70
  Energy efficiency class   A A
  SCOP/C   3.80 3.95
  SCOPnet/C   3.86 4.01
  Annual energy consumption kWh/a 2,429 1,939
  Required back up heating cap at design conditions kW 1.20 0.80
  TOL Tol (temperature operating limit) °C -25 -25
    Pdh (declared heating cap) kW 3.30 2.90
    COPd (declared COP)   1.56 1.56
    Power input kW 2.12 1.86
  TBivalent Tbiv (bivalent temperature) °C -15 -15
    Pdh (declared heating cap) kW 3.59 2.98
    COPd (declared COP)   1.98 1.98
    Power input kW 1.81 1.51
  A Condition (-15°C) Pdh (declared heating cap) kW 3.59 2.98
    COPd (declared COP)   1.98 1.98
    Power input kW 1.81 1.51
  A Condition (-7°C) Pdh (declared heating cap) kW 2.65 2.21
    COPd (declared COP)   3.13 3.39
    Power input kW 0.85 0.65
  B Condition (2°C) Pdh (declared heating cap) kW 1.62 1.35
    COPd (declared COP)   4.89 5.05
    Power input kW 0.33 0.27
  C Condition (7°C) Pdh (declared heating cap) kW 1.04 0.87
    COPd (declared COP)   5.81 5.94
    Power input kW 0.18 0.15
  D Condition (12°C) Pdh (declared heating cap) kW 1.08 1.08
    COPd (declared COP)   7.60 7.60
    Power input kW 0.14 0.14
Power consumption in other than active mode Crankcase heater mode PCK W 0.0  
  Off mode POFF W 1.0  
  Standby mode Cooling PSB W 1.0  
    Heating PSB W 1.0  
  Thermostat-off mode PTO Cooling W 12.0  
      Heating W 12.0  
Cooling Cdc (Degradation cooling)   0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25
Cooling function included Yes Yes
Heating function included Yes Yes
Average climate included Yes Yes
Cold season included Yes Yes
Warm season included No No
Ecolabel logo No No
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61
  Sound power level indoor Cooling Nom. dBA 58 58
  Piping length Cooling Measuring condition m 5.0 5.0
Power factor Nominal Cooling % 98.62 (0.000) 93.37 (0.000)
    Heating % 98.22 (0.000) 97.44 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 3.99 2.66
    Heating A 3.87 3.04
Notes (1) - See separate drawing for electrical data See separate drawing for electrical data
  (2) - Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W] Cooling: T2: indoor temp. 26,6°CDB, 19,4°CWB, outdoor temp. 48°CDB [Btu/hr/W]
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
Power consumption in other than active mode Thermostat-off mode PTO Cooling W   12.0
      Heating W   12.0
  Crankcase heater mode PCK W   0.0
  Off mode POFF W   1.0
  Standby mode Cooling PSB W   1.0
    Heating PSB W   1.0