FTXC25AV1B / RXC25AV1B FTXC35AV1B / RXC35AV1B FTXC50AV1B / RXC50AV1B FTXC60AV1B / RXC60AV1B
Cooling capacity Nom. kW 2.56 3.37 5.48 6.23
Heating capacity Nom. kW 2.84 3.58 5.62 6.40
Power input Heating Nom. kW 0.78 1 1.52 1.63
Nominal efficiency EER   3.08 2.63 3.54 3.44
  COP   3.64 3.58 3.70 3.93
Space cooling Capacity Pdesign kW 2.56 3.37 5.48 6.24
  Energy efficiency class   A++ A++ A++ A++
  SEER   6.14 6.11 6.79 6.21
  Annual energy consumption kWh/a 146 193 283 352
  A Condition (35°C - 27/19) Pdc kW 2.56 3.37 5.48 6.24
    EERd   3.18 2.81 3.50 3.44
  B Condition (30°C - 27/19) Pdc kW 1.89 2.25 4.23 4.76
    EERd   5.12 4.83 5.33 4.72
  C Condition (25°C - 27/19) Pdc kW 1.25 1.48 2.60 2.99
    EERd   8.41 8.13 8.17 7.82
  D Condition (20°C - 27/19) Pdc kW 1.29 1.29 2.07 2.09
    EERd   10.70 11.37 13.35 11.27
Space heating (Average climate) Capacity Pdesign kW 2.41 2.19 3.57 4.16
  Energy efficiency class   A+ A+ A+ A+
  SCOP/A   4.00 4.00 4.30 4.21
  Pdh Heating capacity at -10° kW 1.65 1.80 2.96 3.34
  Annual energy consumption kWh/a 773 768 1,163 1,385
  Required back up heating cap at design conditions kW 0.55 0.39 0.61 0.82
  TOL Tol (temperature operating limit) °C -14 -14 -14 -14
    Pdh (declared heating cap) kW 1.26 1.61 2.70 2.89
    COPd (declared COP)   1.79 2.09 2.17 2.26
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7
    Pdh (declared heating cap) kW 1.95 1.94 3.16 3.68
    COPd (declared COP)   2.43 2.63 2.57 2.73
  A Condition (-7°C) Pdh (declared heating cap) kW 1.95 1.94 3.16 3.68
    COPd (declared COP)   2.43 2.63 2.57 2.73
  B Condition (2°C) Pdh (declared heating cap) kW 1.09 1.29 1.91 2.04
    COPd (declared COP)   4.24 4.14 4.51 4.42
  C Condition (7°C) Pdh (declared heating cap) kW 0.98 0.98 1.52 1.55
    COPd (declared COP)   5.22 5.17 5.59 4.95
  D Condition (12°C) Pdh (declared heating cap) kW 1.15 1.17 1.78 1.77
    COPd (declared COP)   6.42 6.34 7.01 6.71
Space heating (Warm climate) Capacity Pdesignh kW 2.09 2.34 4.46 5.47
  Energy efficiency class   A++ A++ A+++ A+++
  SCOP   4.91 4.97 5.34 5.36
  Annual energy consumption kWh/a 596 659 1,170 1,429.00
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -14 -14 -14 -14.0
    Pdh (declared heating cap) kW 1.26 1.61 2.70 2.89
    COPd (declared COP)   1.79 2.09 2.17 2.26
  TBivalent Tbiv (bivalent temperature) °C 2 2 2 2.00
    Pdh (declared heating cap) kW 2.09 2.34 4.46 5.47
    COPd (declared COP)   2.77 3.06 2.83 2.92
  B Condition (2°C) Pdh (declared heating cap) kW 2.09 2.34 2 2.00
    COPd (declared COP)   2.27 3.06 4.46 5.47
  C Condition (7°C) Pdh (declared heating cap) kW 1.23 1.39 7 7.00
    COPd (declared COP)   5.10 5.14 2.88 3.66
  D Condition (12°C) Pdh (declared heating cap) kW 1.15 1.17 12 12.00
    COPd (declared COP)   6.42 6.34 1.78 1.77
Power consumption in other than active mode Crankcase heater mode PCK W 0 0 0 0
  Off mode POFF W 3,000.0 3,000.0 6,000.0 6,000.0
  Standby mode Cooling PSB W 3,000.0 3,000.0 6,000.0 6,000.0
    Heating PSB W 3,000.0 3,000.0 6,000.0 6,000.0
Pto (Thermostat off) W 35 41 26,000 52,100
Cooling Pcycc W 250 250 250 250
Heating Pcych W 250 250 250 250
Cooling function included Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes
Cold season included No No No No
Warm season included Yes Yes Yes Yes
Ecolabel logo No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 58 60 64 65
  Sound power level indoor Cooling Nom. dBA 53 54 55 61