ATXP20L2V1B / ARXP20L2V1B ATXP20L2V1B / ARXP20L5V1B ATXP20L5V1B / ARXP20L5V1B ATXP25L2V1B / ARXP25L5V1B ATXP25L5V1B / ARXP25L5V1B ATXP25L2V1B / ARXP25L2V1B ATXP35L2V1B / ARXP35L5V1B ATXP35L5V1B / ARXP35L5V1B ATXP35L2V1B / ARXP35L2V1B
Indoor unit ATXP20L2V1B ATXP20L2V1B ATXP20L5V1B ATXP25L2V1B ATXP25L5V1B ATXP25L2V1B ATXP35L2V1B ATXP35L5V1B ATXP35L2V1B
Outdoor unit ARXP20L2V1B ARXP20L5V1B ARXP20L5V1B ARXP25L5V1B ARXP25L5V1B ARXP25L2V1B ARXP35L5V1B ARXP35L5V1B ARXP35L2V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3
  Min. Btu/h 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8
  Min. kcal/h 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8
  Nom. kW 2.00 2.00 2.00 2.50 2.50 2.50 3.50 3.50 3.50
  Nom. Btu/h 6,824.3 6,824.3 6,824.3 8,530.4 8,530.4 8,530.4 11,942.5 11,942.5 11,942.5
  Nom. kcal/h 1,719.7 1,719.7 1,719.7 2,149.6 2,149.6 2,149.6 3,009.5 3,009.5 3,009.5
  Max. kW 2.6 2.6 2.6 3.0 3.0 3.0 4.0 4.0 4.0
  Max. Btu/h 8,871.6 8,871.6 8,871.6 10,236.4 10,236.4 10,236.4 13,648.6 13,648.6 13,648.6
  Max. kcal/h 2,235.6 2,235.6 2,235.6 2,579.5 2,579.5 2,579.5 3,439.4 3,439.4 3,439.4
Heating capacity Min. kW 1.30 1.30 1.30 1.30 1.30 1.30 1.30 1.30 1.30
  Min. Btu/h 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8 4,435.8
  Min. kcal/h 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8 1,117.8
  Nom. kW 2.50 2.50 2.50 3.00 3.00 3.00 4.00 4.00 4.00
  Nom. Btu/h 8,530.4 8,530.4 8,530.4 10,236.4 10,236.4 10,236.4 13,648.6 13,648.6 13,648.6
  Nom. kcal/h 2,149.6 2,149.6 2,149.6 2,579.5 2,579.5 2,579.5 3,439.4 3,439.4 3,439.4
  Max. kW 3.50 3.50 3.50 4.00 4.00 4.00 4.80 4.80 4.80
  Max. Btu/h 11,942.5 11,942.5 11,942.5 13,648.6 13,648.6 13,648.6 16,378.3 16,378.3 16,378.3
  Max. kcal/h 3,009.5 3,009.5 3,009.5 3,439.4 3,439.4 3,439.4 4,127.3 4,127.3 4,127.3
Power input Cooling Min. kW 0.31 0.31 0.31 0.31 0.31 0.31 0.29 0.29 0.29
    Nom. kW 0.50 0.50 0.50 0.66 0.66 0.66 1.01 1.01 1.01
    Max. kW 0.72 0.72 0.72 0.72 0.72 0.72 1.30 1.30 1.30
  Heating Min. kW 0.25 0.25 0.25 0.25 0.25 0.25 0.29 0.29 0.29
    Nom. kW 0.52 0.52 0.52 0.69 0.69 0.69 1.00 1.00 1.00
    Max. kW 0.95 0.95 0.95 0.95 0.95 0.95 1.29 1.29 1.29
Nominal efficiency EER   3.98 3.98 3.98 3.79 3.79 3.79 3.45 3.45 3.45
  COP   4.77 4.77 4.77 4.36 4.36 4.36 4.02 4.02 4.02
  Energy labeling Directive Cooling   A A A A A A A A A
    Heating   A A A A A A A A A
Space cooling Capacity Pdesign kW 2.00 2.00 2.00 2.50 2.50 2.50 3.50 3.50 3.50
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A++ A++
  SEER   6.77 6.77 6.77 6.85 6.85 6.85 6.56 6.56 6.56
  Annual energy consumption kWh/a 104 104 104 128 128 128 187 187 187
  A Condition (35°C - 27/19) Pdc kW 2.00 2.00 2.00 2.50 2.50 2.50 3.50 3.50 3.50
    EERd   3.99 3.99 3.99 3.79 3.79 3.79 3.45 3.45 3.45
    Power input kW 0.50 0.50 0.50 0.66 0.66 0.66 1.01 1.01 1.01
  B Condition (30°C - 27/19) Pdc kW 1.47 1.47 1.47 1.84 1.84 1.84 2.58 2.58 2.58
    EERd   5.10 5.10 5.10 5.14 5.14 5.14 4.36 4.36 4.36
    Power input kW 0.29 0.29 0.29 0.36 0.36 0.36 0.59 0.59 0.59
  C Condition (25°C - 27/19) Pdc kW 1.24 1.24 1.24 1.45 1.45 1.45 1.66 1.66 1.66
    EERd   8.47 8.47 8.47 8.44 8.44 8.44 8.03 8.03 8.03
    Power input kW 0.15 0.15 0.15 0.17 0.17 0.17 0.21 0.21 0.21
  D Condition (20°C - 27/19) Pdc kW 1.32 1.32 1.32 1.34 1.34 1.34 1.36 1.36 1.36
    EERd   13.12 13.12 13.12 13.15 13.15 13.15 13.26 13.26 13.26
    Power input kW 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.10
Space heating (Average climate) Capacity Pdesign kW 2.20 2.20 2.20 2.40 2.40 2.40 2.80 2.80 2.80
  Energy efficiency class   A++ A++ A++ A++ A++ A++ A++ A++ A++
  SCOP/A   4.64 4.64 4.64 4.60 4.60 4.60 4.62 4.62 4.62
  SCOPnet/A   4.68 4.68 4.68 4.64 4.64 4.64 4.67 4.67 4.67
  Pdh Heating capacity at -10° kW 1.98 1.98 1.98 2.09 2.09 2.09 2.32 2.32 2.32
  Annual energy consumption kWh/a 663 663 663 730 730 730 847 847 847
  Required back up heating cap at design conditions kW 0.22 0.22 0.22 0.31 0.31 0.31 0.48 0.48 0.48
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 2.04 2.04 2.04 2.06 2.06 2.06 2.08 2.08 2.08
    COPd (declared COP)   2.24 2.24 2.24 2.26 2.26 2.26 2.28 2.28 2.28
    Power input kW 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91
  TBivalent Tbiv (bivalent temperature) °C -7 -7 -7 -7 -7 -7 -7 -7 -7
    Pdh (declared heating cap) kW 1.94 1.94 1.94 2.11 2.11 2.11 2.47 2.47 2.47
    COPd (declared COP)   3.26 3.26 3.26 3.22 3.22 3.22 3.19 3.19 3.19
    Power input kW 0.60 0.60 0.60 0.66 0.66 0.66 0.77 0.77 0.77
  A Condition (-7°C) Pdh (declared heating cap) kW 1.94 1.94 1.94 2.11 2.11 2.11 2.47 2.47 2.47
    COPd (declared COP)   3.26 3.26 3.26 3.22 3.22 3.22 3.19 3.19 3.19
    Power input kW 0.60 0.60 0.60 0.66 0.66 0.66 0.77 0.77 0.77
  B Condition (2°C) Pdh (declared heating cap) kW 1.18 1.18 1.18 1.29 1.29 1.29 1.51 1.51 1.51
    COPd (declared COP)   4.65 4.65 4.65 4.60 4.60 4.60 4.57 4.57 4.57
    Power input kW 0.25 0.25 0.25 0.28 0.28 0.28 0.33 0.33 0.33
  C Condition (7°C) Pdh (declared heating cap) kW 0.91 0.91 0.91 0.93 0.93 0.93 0.97 0.97 0.97
    COPd (declared COP)   5.84 5.84 5.84 5.77 5.77 5.77 5.83 5.83 5.83
    Power input kW 0.16 0.16 0.16 0.16 0.16 0.16 0.17 0.17 0.17
  D Condition (12°C) Pdh (declared heating cap) kW 1.09 1.09 1.09 1.11 1.11 1.11 1.13 1.13 1.13
    COPd (declared COP)   7.48 7.48 7.48 7.35 7.35 7.35 7.37 7.37 7.37
    Power input kW 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
Space heating (Warm climate) Capacity Pdesignh kW 1.18 1.18 1.18 1.29 1.29 1.29 1.51 1.51 1.51
  Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
  SCOP   5.63 5.63 5.63 5.62 5.62 5.62 5.78 5.78 5.78
  SCOPnet   5.81 5.81 5.81 5.78 5.78 5.78 5.92 5.92 5.92
  Annual energy consumption kWh/a 294 294 294 322 322 322 366 366 366
  Required back up heating cap at design conditions kW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  TOL Tol (temperature operating limit) °C -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (declared heating cap) kW 2.04 2.04 2.04 2.06 2.06 2.06 2.08 2.08 2.08
    COPd (declared COP)   2.24 2.24 2.24   2.26 2.26   2.28 2.28
    Power input kW 0.91 0.91 0.91   0.91 0.91   0.91 0.91
  TBivalent Tbiv (bivalent temperature) °C 2 2 2   2 2   2 2
    Pdh (declared heating cap) kW 1.18 1.18 1.18   1.29 1.29   1.51 1.51
    COPd (declared COP)   4.65 4.65 4.65   4.60 4.60   4.57 4.57
    Power input kW 0.25 0.25 0.25   0.28 0.28   0.33 0.33
  B Condition (2°C) Pdh (declared heating cap) kW 1.18 1.18 1.18   1.29 1.29   1.51 1.51
    COPd (declared COP)   4.65 4.65 4.65   4.60 4.60   4.57 4.57
    Power input kW 0.25 0.25 0.25   0.28 0.28   0.33 0.33
  C Condition (7°C) Pdh (declared heating cap) kW 0.91 0.91 0.91   0.93 0.93   0.97 0.97
    COPd (declared COP)   5.84 5.84 5.84   5.77 5.77   5.83 5.83
    Power input kW 0.16 0.16 0.16   0.16 0.16   0.17 0.17
  D Condition (12°C) Pdh (declared heating cap) kW 1.09 1.09 1.09   1.11 1.11   1.13 1.13
    COPd (declared COP)   7.48 7.48 7.48   7.35 7.35   7.37 7.37
    Power input kW 0.15 0.15 0.15   0.15 0.15   0.15 0.15
Power consumption in other than active mode Crankcase heater mode PCK W 0.0 0.0 0.0   0.0 0.0   0.0 0.0
  Off mode POFF W 1.0 1.0 1.0   1.0 1.0   1.0 1.0
  Standby mode Cooling PSB W 1.0 1.0 1.0   1.0 1.0   1.0 1.0
    Heating PSB W 1.0 1.0 1.0   1.0 1.0   1.0 1.0
  Thermostat-off mode PTO Cooling W 12 12 12   12 12   12 12
      Heating W 12 12 12   12 12   12 12
Cooling Cdc (Degradation cooling)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Heating Cdh (Degradation heating)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Cooling function included Yes Yes Yes Yes Yes Yes Yes Yes Yes
Heating function included Yes Yes Yes Yes Yes Yes Yes Yes Yes
Average climate included Yes Yes Yes Yes Yes Yes Yes Yes Yes
Cold season included No No No No No No No No No
Warm season included Yes Yes Yes Yes Yes Yes Yes Yes Yes
Ecolabel logo No No No No No No No No No
Eurovent Sound power level outdoor Cooling Nom. dBA 60 60 60 60 60 60 62 62 62
  Sound power level indoor Cooling Nom. dBA 55 55 55 55 55 55 58 58 58
  Piping length Cooling Measuring condition m 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0
Power factor Nominal Cooling % 88.6 (0.000) 88.6 (0.000) 88.6 (0.000) 88.6 (0.000) 88.6 (0.000) 88.6 (0.000) 81.9 (0.000) 81.9 (0.000) 81.9 (0.000)
    Heating % 85.5 (0.000) 85.5 (0.000) 85.5 (0.000) 85.5 (0.000) 85.5 (0.000) 85.5 (0.000) 86.0 (0.000) 86.0 (0.000) 86.0 (0.000)
Current Nominal running current (RLA) - 50Hz Cooling A 2.47 2.47 2.47 3.25 3.25 3.25 5.42 5.42 5.42
    Heating A 2.67 2.67 2.67 3.50 3.50 3.50 5.03 5.03 5.03
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data See separate drawing for electrical data (3) - See separate drawing for electrical data (3) - See separate drawing for electrical data
Space heating (Warm climate) TOL COPd (declared COP)         2.26     2.28    
    Power input kW       0.91     0.91    
  TBivalent Tbiv (bivalent temperature) °C       2     2    
    Pdh (declared heating cap) kW       1.29     1.51    
    COPd (declared COP)         4.60     4.57    
    Power input kW       0.28     0.33    
  B Condition (2°C) Pdh (declared heating cap) kW       1.29     1.51    
    COPd (declared COP)         4.60     4.57    
    Power input kW       0.28     0.33    
  C Condition (7°C) Pdh (declared heating cap) kW       0.93     0.97    
    COPd (declared COP)         5.77     5.83    
    Power input kW       0.16     0.17    
  D Condition (12°C) Pdh (declared heating cap) kW       1.11     1.13    
    COPd (declared COP)         7.35     7.37    
    Power input kW       0.15     0.15    
Power consumption in other than active mode Crankcase heater mode PCK W       0.0     0.0    
  Off mode POFF W       1.0     1.0    
  Standby mode Cooling PSB W       1.0     1.0    
    Heating PSB W       1.0     1.0    
  Thermostat-off mode PTO Cooling W       12     12    
      Heating W       12     12